Cooker Hood / User Manual
11 / EN
3
Operation of the appliance
Disconnect the hood from the mains supply. This
appliance is equipped with 3 W halogen lamps. To
replace the halogen lamps, press the lamp down-
wards from the rear section of the lamp holder to
release the lamp. Then turn it counterclockwise by
1/4 tour and remove it. Perform the above steps in
reverse order to fit the new lamps.
C
You may procure lamps from
Authorised Service Agents.
Bulb
Bulb Power
3 W
Holder / Socket
GZ 10
Bulb Voltage
220 - 240 V
Size
53 x 50 mm
ILCOS Code
DR/F3-220-240-GZ10-50-53
Luminous flux
260 lm
Correlated colour
temperature
3000 K
This product contains a light source of energy ef-
ficiency class “F”.
3.6 Operation with chimney
connection
•
Vapour is extracted through the
flue duct, which is fastened to
the connection head on the
hood.
•
The diameter of the flue duct must be the same
as the connection ring. In horizontal settings, the
pipe has to have a slight upward slope (around
10º) so that the air can exit the room easily.
3.7 Operation without chimney
connection
•
Air is filtered through the carbon
filter and recirculated in the
room. Carbon filter is used
when it is impossible to use a
flue in the house.
•
In flueless use, remove the flaps inside the flue
adapter.
•
Remove the Grease filter. To install the carbon
filter, fit the filter to the tabs by centring it on
the plastic piece on both sides of the fan body.
tighten it by turning right or left.
•
Replace Grease filter.