FITTED WITH
BS 1362 13A FUSE ALWAYS
FIT BS 1362 REPLACEMENT
CARTRIDGE FUSE
GREEN &
YELLOW
OR
GREEN
N
BLUE
OR
BLACK
L
BROWN
OR
RED
22mm.
6mm.
6mm.
6mm.
32mm.
12mm.
FUSE
CORD GRIP
TRANSPORTATION INSTRUCTIONS
1.
The appliance should be transported only in a vertical upright position. The
packing as supplied must be intact during transportation.
2.
If during the course of transport the appliance has to be transported
horizontally, it must only be laid on its left hand side when standing in the front
of the appliance. After bringing it to upright position,it must not be operated
for at least 4 hours to allow the system to settle.
3.
Failure to comply with the above instructions could result in damage occuring
to the appliance. The manufacturer will not be held responsible if these
instructions are disregarded.
4.
The appliance must be protected against rain, moisture and other
atmospheric influences.
5.
When positioning your appliance take care not to damage your flooring,
kitchen furniture, related parts and doors, pipes, wall coverings etc. Do not
move the appliance by pulling by the door.
6.
Empty any water in the drain tray before moving. See section ‘Defrosting’ and
‘Care & cleaning’ for further information.
7.
Make sure that the defrost water pipe at the back of the product is fixed to the
plastic evaporating pan on the top of the compressor, to avoid defrost water
spillage on the floor.
IMPORTANT :
Care must be taken while cleaning / carrying the appliance to
avoid touching the bottom of the condenser metal wires at the back of the
appliance as you might injure your fingers and hands.
Do not attempt to sit or stand on top of your appliance as it is not designed for
such use. You could injure yourself or damage the appliance.
"IMPORTANT:
Make sure that mains cable is not caught under the appliance
during and after carrying / moving the appliance, to avoid the mains cable
becoming cut or damaged."
Do not allow children to play with the appliance or tamper with the controls.
BEKO
plc declines to accept any liability should the instructions not be
followed.
IMPORTANT
INSTALLATION INSTRUCTIONS
1.
The space in the room where the appliance is installed must not be smaller
than 10 cubic metres.
2.
See pages 16 to 23 for detailed Installation Instructions including reversing
door opening direction.
3.
Do not put your fridge freezer in a cold room where the temperature is likely
to go below +5 degrees C (41 degrees F) during night time and/or especially
in winter.
4
3
ELECTRICAL REQUIREMENTS
Before you insert the plug into the wall socket make sure that the voltage and the
frequency shown in the rating plate inside the appliance corresponds to your
electricity supply.
Rating label is on the left hand side of fridge inner liner.
We recommend that this appliance be connected to the mains supply via a
suitable switched and fused socket. The appliance must be positioned so that
the plug is accessible.
Should the mains lead of the appliance become damaged or should it need
replacing at any time, it must be replaced by a special purpose made mains lead
which can only be obtained from a
BEKO
Authorised Service Agent.
WARNING! THIS APPLIANCE MUST BE EARTHED
If the fitted moulded plug is not suitable for your socket, then the plug should be
cut off and an appropriate plug fitted. Destroy the old plug which is cut off as a
plug with bared cord could cause a shock hazard if inserted into a socket
elsewhere in the house.
The moulded plug on this appliance incorporates a 13 A fuse. Should the fuse
need to be replaced an ASTABEAB approved BS 1362 fuse of the same rating must
be used. Do not forget to refit the fuse cover. In the event of losing the fuse cover
the plug must not be used until a replacement fuse cover has been fitted. Colour
of the replacement fuse cover must be the same colour as that visible on the pin
face of the plug. Fuse covers are available from any good electrical store.
IMPORTANT! FITTING A DIFFERENT PLUG
As the colours of the wires in the
mains lead of this appliance may
not correspond with the coloured
markings identifying the terminals
in your plug proceed as follows:
(See diagram).
1.
Connect the green-yellow or
green (Earth) wire to the terminal
in the plug marked 'E' or with
the symbol or coloured
green and yellow or green.
2.
Connect the blue (Neutral) wire
to the terminal in the plug
marked 'N' or coloured black.
3.
Connect the brown (Live) wire to
the terminal in the plug marked 'L'
or coloured red.
With alternative plugs a 13 A fuse must be fitted either in the plug or adaptor or
in the main fuse box.
If in doubt contact a qualified electrician.