Installation and operating manual
EN
20 BEKOMAT
®
3/6 CO Ex, 3/6 E Ex
4.3. Electrical connections
The unit must be connected to an intrinsically safe power supply as shown in the wiring diagram.
NOTE
Information regarding intrinsically safe power supply
For more information regarding the intrinsically safe power supply, see accessories 7.4,
page 24. For additional information regarding the connection of the intrinsically safe power
supply, see separate installation and operating manual.
BEKO TECHNOLOGIES
www.beko-technologies.com
BEKOMAT
®
ALARM / TEST
NETZ / POWER
TEST
4 x
1. Loosen the screws of the electronics housing and remove the
housing cover.
1
2. Loosen the armoured conduit fittings
1
.
1
3. Feed the cable through the cable duct (armoured conduit fitting)
and connect it according to the wiring diagram 4.2, page 19. Then
screw in the armoured conduit fittings.
BEKO TECHNOLOGIES
www.beko-technologies.com
BEKOMAT
®
ALARM / TEST
NETZ / POWER
TEST
4 x
4. Mount the housing cover and tighten the screws.