Installation and operating manual
EN
8 BEKOMAT
®
3/6 CO Ex, 3/6 E Ex
1.5. Proper use
The BEKOMAT
®
is an electronically level-controlled condensate drain for compressed air systems. The BEKOMAT
®
is able to drain condensate from the plant components at operating pressure and with virtually no compressed air
loss. The BEKOMAT
®
version with no-load drain/no-load valve caters for plants with low operating pressure, for
instance in connection with multi-stage compressors.
This model must always be equipped with original spare parts and accessories.
The BEKOMAT
®
3/6 CO Ex or 3/6 E Ex can be operated in potentially explosive atmospheres, provided that the
unit bears the following ATEX-/EPL mark:
II 2G Ex ib IIB T4 Gb
Admissible media:
Ethane, methane, coal gas (town gas), compressor oils, diesel fuel, ethylene,
propane, heating oil, fluid of DGRL group ll
For more information regarding the ATEX classification and mark, see
Do not install the BEKOMAT
®
in areas that are exposed to frost.
Operate the unit only for the intended purpose and within the limit range specified in the technical data. Do not
operate the unit with any media (fluids, gas/vapour mixtures) than those listed above. Any other use of the unit is
deemed improper and poses a risk to persons, property and the environment.
1.6. Warranty and liability
All warranty shall be voided, if the BEKOMAT
®
is used improperly, for a purpose other than the intended or is
operated outside the limits specified in the technical data. In such cases, the manufacturer shall also reject any
liability for damage. Improper operation includes:
•
Incorrect installation, commissioning or operation; insufficient maintenance
• Operation with defective components
•
Non-compliance with the instructions in this document, in particular the safety instructions
•
Modification of the unit
•
Use of third-party spare parts that have not been approved by the manufacturer