6.2 Assembly conditions
Wrong
Right
Description / explanation
> 3%
Continuous slope > 3
% in hoses
• When using hoses as the feed line, ensure a
continuous slope > 3 %.
• Do not form water pockets.
> 3%
Continuous slope > 3
% in pipes
• When installing the feed line pipe, ensure a
continuous slope > 3 %.
• Do not form water pockets.
> 10 m (32.8 ft)
> 5 m (16.25 ft)
≤
10 m (32.8 ft)
≤
5 m (16.25 ft)
Drain line version
•
Do not use shut-off valves in the drain line.
• Only connect the
BEKOMAT
®
to the drain
line using a hose.
0
The hose compensates for assembly
tolerances, vibrations and thermal
expansion.
• Do not install the drain line on storage or
transportation surfaces.
• The drain line may be a maximum
of
10 m (32.8 ft) long and installed at a
maximum of 5 m (16.25 ft) rise.
0
The minimum operating pressure
increases by 0.1 bar(g) (1.5 psi(g)) per
metre of incline.