Illustration
Description / explanation
Power
Alarm
Service
TEST
Discharge procedure (TEST button pressed briefly)
•
The red ALARM LED is off
• The green POWER LED is on (100 % brightness) while
the solenoid valve is cycling
Power
Alarm
Service
TEST
Power
Alarm
Service
TEST
n = ∞
Pre-alarm (TEST button pressed > 1 minute and
< 5 minutes)
•
The red ALARM LED flashes
• The green POWER LED is on (100 % brightness)
Power
Alarm
Service
TEST
Alarm (TEST button pressed > 5 minutes)
• The red ALARM LED is on
• The green POWER LED is on (50 % brightness)
Power
Alarm
Service
TEST
n = ∞
Power
Alarm
Service
TEST
Alarm mode (malfunctioning of condensate discharge)
•
The red ALARM LED flashes
• The green POWER LED is on (50 % brightness)
0
The solenoid valve is cycling every 4 minutes
After the malfunction has been eliminated, the
BEKOMAT
®
automatically switches to normal operation.
Power
Alarm
Service
TEST
Maintenance signal
•
The green POWER LED flashes.
0
Change Service-Units
For further information about fault indications during operation, see “15. Troubleshooting” on page 63.
Original installation and operation manual
BEKOMAT
®
33iU / 33iU CO
43 | 68