Via the inlet line (1) the condensate flows into the
BEKOMAT
®
33U / 33U CO and accumulates in the
housing (2).
A capacitively functioning sensor (3) continuously reg-
isters the filling level and relays a signal to the elec-
tronic control as soon as the container is filled.
The pilot valve (4) is activated and the membrane (5)
opens the outlet line to discharge the condensate (6).
When the BEKOMAT
®
33U / 33U CO is empty, the
outlet line is reclosed tightly in time before unneces-
sary compressed-air losses occur.