Installation and operating manual
BEKOMAT
®
8/9
17
1.D
1.1
L1
N
PE
PE
PE
N
V1
N.C
COM
N.O
2.0
2.1
3.0
3.1
3.2
Netzteil
Power supply
Netzanschluss
Power
Magnetventil
Solenoid valve
Alarmkontakt
Alarm contact
Gehäuse Housing
Ventilsteuerung
Valve control
Zeitauswertung
Time analysis
Sensor-Kreis
Sensor loop
Oscillator
Alarmkontrolle
Alarm monitoring
Sensor
MAX
MIN
Connecting power cable:
• Push the cable through the cable screw and connect it to terminals
L1, N, PE
Alarm signal line:
The device is equipped with a floating alarm relay (changeover) for the transfer of alarm signals in the event of a fault:
• push the cable through the second cable screw and connect it
N.C. – COM
:
Contact is made in the event of a fault or power failure (fail-safe contact)
N.O. – COM
:
Contact is made during normal operation
•
Tighten cable screw(s)
• Mount the top part of the cover and tighten the screws
• Mount the housing cover and tighten the screws