Instructions for installation and operation 

Replacement unit 

Service-Unit BEKOMAT

®

 31U / 31U F 

(SUBM31U / SUBM31UF)

 

 

 

 

 

01

-16

10

 

 

 

Summary of Contents for BEKOMAT SUBM31U

Page 1: ...EN english Instructions for installation and operation Replacement unit Service Unit BEKOMAT 31U 31U F SUBM31U SUBM31UF 01 1610 ...

Page 2: ...2 Service Unit BEKOMAT 31U 31U F ...

Page 3: ...Service Unit BEKOMAT 31U 31U F 3 1 Pictograms and symbols 4 2 Safety instructions 4 3 Technical data 6 4 Inspection and maintenance 7 5 Elements and components 10 6 Recommended spare parts 11 ...

Page 4: ...ce Therefore it is imperative for the service technician and the responsible operator technical staff to read these operating instructions prior to installation start up and maintenance The operating instructions must be accessible at any time at the place of application of the BEKOMAT 31U In addition to these operating instructions local or national regulations must be complied with if necessary ...

Page 5: ...t drainage Use genuine spare parts only This is imperative to ensure perfect functioning Pos 13 Beko Technische D okumentati on Sicher hei t Zusatz Sicherheitshi nweise BM31 32 SA 31U 32U SA 0 mod_1185351496993_2901 docx 6480 1 Additional advice The removed control unit has no IP degree of protection During installation use spanner flat at the feed pipe wrenchsize SW27 as a back rest The service u...

Page 6: ...Leistg 5 mod_1358843578945_2901 docx 30450 1 min max operating pressure see type plate 0 8 16 bar 12 230 psi or 1 2 16 bar 17 230 psi min max temperature see type plate 1 60 C 34 140 F or 1 70 C 34 158 F Condensate inflow G NPT internal max screw in depth 13 5 mm Condensate outflow G Ø 8 10 mm hose connector Condensate oil contaminated oil free Housing aluminium plastic glass fibre reinforced Weig...

Page 7: ...31U 32U 33U 7 mod_1390467197804_2901 docx 38043 1 Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 When the control unit is open service and installation works must only be undertaken when the system is deactivated The removed control unit has no IP degree of protection All types of electrical works must be carried out by authorised and q...

Page 8: ...efore skin contact should be avoided Condensate is subject to mandatory waste disposal As such it must be collected in suitable containers and disposed of or processed properly Pos 28 Beko Technische D okumentati on Wartung BEKOM AT Wartung BM 31U 32U Ser vice Uni t 5 mod_1358510276825_2901 docx 30412 1 1 Prior to the replacement of the service unit a reset needs to be carried out The control unit...

Page 9: ...ignation and colour of the arresting hook 2 Check whether or not the sealing mat 11 or the sensor tube plate 14 with contact springs 13 are clean dry and free from impurities 3 Introduce the sensor 12 into the sensor tube plate 14 4 Hang the hook 15 of the control unit 1 in the sensor tube plate 14 5 Press the control unit 1 against the service unit 5 and snap into place Start up subsequent to mai...

Page 10: ...31U Ser vice U nit 6 mod_1378727822822_2901 docx 33608 1 1 Screw 3 5 x 10 2 Upper part of the cover 3 Moulded gasket 4 Printed circuit board 5 Sensor 6 Lower part of the cover 7 Cable bushing 8 Sealing mat 9 Service unit 10 Hose connector G 11 O ring 20 x 2 12 Intermediate adapter 13 Screw M6 x 12 14 O ring 14 x 1 78 15 Angle adapter 16 Design shell 17 Cord packing only previous version Pos 32 Sei...

Page 11: ...or BM31 or BM31BI Service Unit SUBM31UF for BM31UF or BM31UBIF or BM31UIFBIF or BM31F or BM31BIF or BM31IFBIF 8 9 11 4023607 4023608 Gasket kit 3 8 11 17 4024386 Design shell 16 4010164 Connection adapter 11 12 13 14 15 4010155 Not for BEKOMAT 31U built in or BEKOMAT 31U built in F Pos 35 Beko Technische D okumentati on Globale Texte Hinweis Ü bersetzg d Orig anl eitg 1 mod_1260433478358_2901 docx...