Split-type room air conditioner / Installation Manual
15 / 120 EN
C
Note about wall hole:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole
(see Drill wall hole for connective piping step) for the signal cable and refrigerant
piping that connect the indoor and outdoor units. The default position for all piping
is the right side of the indoor unit (while facing the unit). However, the unit can
accommodate piping to both the left and right.
Refer to the following diagram to ensure proper distance from walls and ceiling:
15cm (5.9in) or more
12cm (4.75in)
or more
12cm (4.75in)
or more
2.3m (90.55in) or more
Fig. 5.1
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will mount the indoor unit.
1. Remove the screw that attaches the mounting plate to the back of the indoor unit.
2. Place the mounting plate against the wall in a location that meets the standards in the Select
Installation Location step. (See Mounting Plate Dimensions for detailed information on mounting
plate sizes.)
3. Drill holes for mounting screws in places that:
•
have studs and can support the weight of the unit
•
correspond to screw holes in the mounting plate
4. Secure the mounting plate to the wall with the screws provided.
5. Make sure that mounting plate is flat against the wall.
5
Indoor unit installation
Summary of Contents for BEVPI 090
Page 118: ......
Page 119: ......
Page 120: ...www beko com ...
Page 121: ...Air conditioner remote control User Manual EN ...
Page 128: ...8 24 EN Air conditioner remote control User Manual 3 Handling the remote control ...
Page 142: ......
Page 143: ......
Page 144: ...www beko com ...
Page 145: ......
Page 166: ......
Page 167: ......
Page 168: ...www beko com ...