Split-type room air conditioner / Installation Manual
19 / 120 EN
Knock-out Panel
Fig. 5.3
3. Use scissors to cut down the length of the insulating sleeve to reveal about 15cm (6in) of the
refrigerant piping. This serves two purposes:
•
To facilitate the Refrigerant Piping Connection process
•
To facilitate Gas Leak Checks and enable you to check for dents
4. If existing connective piping is already embedded in the wall, proceed directly to the Connect
Drain Hose step. If there is no embedded piping, connect the indoor unit’s refrigerant piping to
the connective piping that will join the indoor and outdoor units. Refer to the Refrigerant Piping
Connection section of this manual for detailed instructions.
5. Based on the position of the wall hole relative to the mounting plate, determine the necessary
angle of your piping.
6. Grip the refrigerant piping at the base of the bend.
7. Slowly, with even pressure, bend the piping towards the hole. Do not dent or damage the piping
during the process.
C
Note on piping angle
Refrigerant piping can exit the indoor unit from four different angles:
•
Left-hand side
•
Left rear
•
Right-hand side
•
Right rear
Refer to Fig. 5.4 fo r details.
5
Indoor unit installation
Summary of Contents for BEVPI 090
Page 118: ......
Page 119: ......
Page 120: ...www beko com ...
Page 121: ...Air conditioner remote control User Manual EN ...
Page 128: ...8 24 EN Air conditioner remote control User Manual 3 Handling the remote control ...
Page 142: ......
Page 143: ......
Page 144: ...www beko com ...
Page 145: ......
Page 166: ......
Page 167: ......
Page 168: ...www beko com ...