Split-type room air conditioner / Installation Manual
53 / 120 EN
12
Installation instructions
12.1 F-Gas instruction
This product contains fluorinated greenhouse gases covered by the Kyoto protocol.
The fluorinated greenhouse gases are contained in hermetically sealed equipment.
Installs, services, maintains, repairs, checks for leaks or decommissions equipment and product
recycling should be carried out by natural persons that hold relevant certificates.
If the system has a leakage detection system installed, leakage checks should be performed at least
every 12 months, make sure system operate properly.
If product must be performed leakage checks, it should specify Inspection cycle, establish and save
records of leakage checks.
C
Note:
For hermetically sealed equipment, portable air conditioner, window air
conditioner and dehumidifier, if CO
2
equivalent of fluorinated greenhouse gases is less
than 10 tonnes, it should not perform leakage checks.