Applied EU directives and harmonised standards
CLEARPOINT® L 205 – L295 V
15
The place of installation, installation conditions
The pressure and temperature of the inlet air
The ambient temperature
The device is supplied as accepted in the factory. The operator only needs to establish the connections
with the compressed-air system, which is described in the following chapters.
WARNING!
Improper use!
The following is considered as improper use and is prohibited:
Exceeding the max. permissible operating pressure
Exceeding the max. permissible operating temperature
Exceeding the max. permissible volume flow
Employment of the CLEARPOINT
®
V in hazardous areas
All individual cases of application which are not described as proper us
7
Applied EU directives and harmonised standards
Applied EU directives:
97/23/EC
Pressure Equipment Directive
Harmonised standards applied:
EN 10216-2:
Seamless steel tubes for pressure purposes. Technical delivery conditions -
Part 2: Non-alloy and alloy steel tubes with specified elevated temperature
properties
EN 10028-2:
Flat products made of steels for pressure purposes - Part 2: Non-alloy and alloy
steels with specified elevated temperature properties
EN 10242:
Threaded pipe fitting in malleable cast iron
AD-2000 bulletins