Installation
28
CLEARPOINT® L 205 – L295 V
13.2 Minimum requirements
13.2.1 Filtration of the compressed air
Prefilter:
Super-fine filter (S) with condensate drain
max. residual content oil aerosols 0.01 mg/m³ at 20°C
Afterfilter:
Dust filter (F) with manual drain
Particle classification 1 µm
13.2.2 Water content of the compressed air
Max. permissible residual humidity:
< 30%
13.2.3 Inlet temperature of the compressed air
Recommended inlet temperature:
+ 35°C
Non-observance of the indicated minimum requirements regarding the installation and
permissible operating parameters can lead to drastic reduction of the service life of the
CLEARPOINT
®
V activated-carbon adsorber.