Installation
30
CLEARPOINT® L 205 – L295 V
13.3.2 Installation diagram CLEARPOINT
®
V with an adsorption dryer
1
Super-fine filter (S) with BEKOMAT
2
Adsorption dryer
3
Dust filter (F) with manual drain
4
Activated-carbon adsorber
Oil-and grease-free
zone
5
Dust filter (F) with manual drain
6
Sensor unit METPOINT
®
OCV
7
Evaluation unit with user interface METPOINT
®
OCV
H1/H2
Shut-off valves of the measuring section
H3
Shut-off valve of the bypass
H4
Vent valve of the measuring section
The depicted installation shows another installation possibility of the CLEARPOINT
®
V activated-carbon
adsorber that meets the minimum requirements. Other types of installation are possible (provided that
they meet the defined operating conditions).
For service measures, it is recommended to install a bypass around the CLEARPOINT
®
V. This applies
generally to all components to be serviced in compressed-air systems. Please observe that this bypass
must also be free from oil and grease!