Troubleshooting and fault elimination
38
CLEARPOINT® L 205 – L295 V
15.2 Status and alarm indications
Residual oil content too high
Possible cause of failure
Fault elimination
Inlet volume flow too high
Reduce the inlet volume flow
Operating pressure too low
Increase the operating pressure
Compressed-air temperature at the inlet too high
Reduce the compressed-air temperature
at the inlet
Install a precooler, if required
Inlet filter elements exhausted
Pressure difference too high
Replace the inlet filter elements
Use of oil-contaminated filters or filter elements
downstream of the activated-carbon adsorber
Use of BEKO filters and filter elements in
an oil- and grease-free version
Oil-contaminated circuit sections between the
activated-carbon adsorber and the measuring
point
Clean the pipesection or install a new
pipesection
Condensate drainage upstream of the activated-
carbon adsorber does not work
Check the functioning of the condensate
drain (at the inlet filter), repair or replace it,
if required
Max. absorption capacity of the activated carbon
reached
Replace the activated carbon