Troubleshooting and fault elimination
CLEARPOINT® L 205 – L295 V
39
Container pressure too low / Operating pressure in the system too low
Possible cause of failure
Fault elimination
Pressure difference of the inlet filter is too high
Check the pressure drop via the inlet filter
Replace the filter element, if required
The compressed-air system upstream of the
activated-carbon adsorber is pressureless
Check the compressed-air system
upstream of the activated-carbon adsorber
Eliminate any faults
Larger amounts of wear debris in the system:
clogged compressed-air distributor or filter
elements
Replace the dust filter element
Replace the activated carbon
Clean the compressed-air distributor
Verify the operating conditions (pulsation,
volume flow)
NOTE!
In the event of malfunctions which are not listed here or which cannot be eliminated, please
contact BEKO TECHNOLOGIES GMBH.