43
Heatless Desiccant Dryers
|
Instruction Manual
Section 9:
Technical Data
Dryer Sizing Table
Dryer
Model
Unit
Inlet Flow Rate
Dryer
Config.
Dimension inches (mm)
Weight
SCFM
Nm³/hr
A
B
C
lb
Kg
ACC 4
3
/
8
4
7
simplex
17.52 (445)
11.06 (281)
3.6 (92)
28.7
13.0
ACC 6
3
/
8
6
10
simplex
19.84 (504)
11.06 (281)
3.6 (92)
30.9
14.0
ACC 8
3
/
8
8
14
simplex
22.20 (564)
11.06 (281)
3.6 (92)
33.1
15.0
ACC 10
3
/
8
10
17
simplex
24.96 (634)
11.06 (281)
3.6 (92)
36.4
17.0
ACC 15
3
/
8
15
25
simplex
32.05 (814)
11.06 (281)
3.6 (92)
43.0
20.0
ACC 25
3
/
8
25
42
simplex
41.89 (1064)
11.06 (281)
3.6 (92)
52.9
24.0
ACC 35
3
/
8
35
59
simplex
57.44 (1459)
11.06 (281)
3.6 (92)
68.4
31.0
Pressure Correction Factor (PCF)
Operating Pressure
psig
58
73
87
102
116
131
145
160
174
189
203
218
232
barg
4
5
6
7
8
9
10
11
12
13
14
15
16
PCF*
0.62
0.75
0.87
1.00
1.12
1.25
1.37
1.50
1.62
1.75
1.87
2.00
2.12
*Always use the pressure correction factor (PCF) closest to actual inlet pressure condition
Temperature Correction Factor (TCF)
Temperature
°F
68
77
86
95
104
113
122
°C
20
25
30
35
40
45
50
TCF
1.07
1.06
1.04
1.00
0.88
0.67
0.55
Dewpoint Correction Factor (DCF)
Temperature
°F
-40
-94
°C
-40
-70
DCF
1.0
0.7
Filter Mounting Holes M6
(44 mm)
1.75”
Outlet Port
3/8” NPT
Inlet Port
3/8” NPT
C
B
A
Figure 9.1: Models 4 SCFM – 35 SCFM