DRYPOINT® RS 15-550 HP50 NA
3
Contents
1
Name plate
5
2
Safety instructions
5
2.1
Safety pictograms in accordance with DIN 4844
6
2.2
Signal words in accordance with ANSI
8
2.3
Overview of the safety instructions
8
3
Proper use
10
4
Exclusion from a field of application
10
5
Operating instructions in accordance with the 2014/68/EU Pressure Equipment Directive 11
6
Transport
11
7
Storage
11
8
Installation
12
8.1
Place of installation
12
8.2
Installation plan
13
8.3
Correction factors
14
8.4
Connection to the compressed-air system
15
8.5
Connection to the cooling-water network
15
8.6
Minimum cooling water requirements:
15
8.7
Electrical connections
16
8.8
Condensate drain
16
9
Start-up
16
9.1
Preliminary stages
16
9.2
Initial start-up
17
9.3
Shut down and restart
18
10
Technical data
19
10.1
Technical data DRYPOINT RS 15-180 HP50 NA 1/115/60
19
10.2
Technical data DRYPOINT RS 15-550 HP50 NA 1/230/60
20
10.3
Technical data DRYPOINT RS 180-550 3phase HP50 NA 3/460/60
21
10.4
Technical data DRYPOINT RS 180-550 3phase HP50 NA 3/380/60
22
11
Technical description
23
11.1
Control panel
23
11.2
Functional description
23
11.3
Flow chart (air-cooled)
24
11.4
Flow chart (water-cooled)
24
11.5
Refrigerating compressor
25
11.6
Condenser (air-cooled)
25
11.7
Condenser (water-cooled)
25
11.8
Cooling-water regulating valve
25
11.9
Filter dryer
25
11.10
Capillary tube
25
11.11
Air-to-air heat exchanger
25
11.12
Air-to-refrigerant heat exchanger
25
11.13
Condensate separator
25
11.14
Hot-gas bypass valve
25
11.15
Refrigerant pressure switches LPS
– HPS
26
11.16
Safety temperature switch TS
26
11.17
Compressor crankcase heater (RS 180-550 3phase)
26
11.18
Electronic controller DMC35 (RS 15-40)
27
11.18.1
How to switch on the dryer
27
11.18.2
How to switch off the dryer
27
11.18.3
How a service warning / alarm is displayed
27
11.18.4
How is controlled the condenser fan
28
11.18.5
How is controlled the drain solenoid valve
28
11.18.6
How to display the total hours of operation
28
11.18.7
How to change the operating parameters
28
11.19
Electronic controller DMC34
29
11.19.1
How to switch on the dryer
29
11.19.2
How to switch off the dryer
29
11.19.3
How to display the operating parameters
29
Summary of Contents for DRYPOINT RS 100-E HP50 NA
Page 22: ...22 DRYPOINT RS 15 550 HP50 NA 10 4 Technical data DRYPOINT RS 180 550 3phase HP50 NA 3 380 60 ...
Page 40: ...Appendices 40 DRYPOINT RS 15 550 HP50 NA 13 1 2 Dryer dimensions DRYPOINT RS 50 80 HP50 NA ...
Page 41: ...Appendices DRYPOINT RS 15 550 HP50 NA 41 13 1 3 Dryer dimensions DRYPOINT RS 100 140 HP50 NA ...
Page 42: ...Appendices 42 DRYPOINT RS 15 550 HP50 NA 13 1 4 Dryer dimensions DRYPOINT RS 180 350 HP50 NA ...
Page 43: ...Appendices DRYPOINT RS 15 550 HP50 NA 43 13 1 5 Dryer dimensions DRYPOINT RS 450 550 HP50 NA ...
Page 47: ...Appendices DRYPOINT RS 15 550 HP50 NA 47 13 2 2 Exploded diagram DRYPOINT RS 15 40 HP50 NA ...
Page 48: ...Appendices 48 DRYPOINT RS 15 550 HP50 NA 13 2 3 Exploded diagram DRYPOINT RS 50 80 HP50 NA ...
Page 49: ...Appendices DRYPOINT RS 15 550 HP50 NA 49 13 2 4 Exploded diagram DRYPOINT RS 100 140 HP50 NA ...
Page 59: ...Appendices DRYPOINT RS 15 550 HP50 NA 59 13 3 2 Electric diagram DRYPOINT RS 15 40 HP50 NA ...
Page 60: ...Appendices 60 DRYPOINT RS 15 550 HP50 NA 13 3 3 Electric diagram DRYPOINT RS 50 80 HP50 NA ...
Page 61: ...Appendices DRYPOINT RS 15 550 HP50 NA 61 13 3 4 Electric diagram DRYPOINT RS 100 140 HP50 NA ...
Page 62: ...Appendices 62 DRYPOINT RS 15 550 HP50 NA 13 3 5 Electric diagram DRYPOINT RS 180 260 HP50 NA ...
Page 63: ...Appendices DRYPOINT RS 15 550 HP50 NA 63 13 3 6 Electric diagram DRYPOINT RS 350 HP50 NA ...
Page 64: ...Appendices 64 DRYPOINT RS 15 550 HP50 NA 13 3 7 Electric diagram DRYPOINT RS 450 550 HP50 NA ...
Page 71: ...DRYPOINT RS 15 550 HP50 NA 71 ...