Installation
24
METPOINT
®
OCV
10.4 Installation diagram METPOINT
®
OCV with oil-free compression
1 Compressor with oil-free compression
2 Cyclone separator with BEKOMAT
3 Compressed-air tank
4 BEKOMAT for the tank drainage
5 Universal filter (G) with BEKOMAT
6 Minimum requirement: refrigeration dryer
7 Super-fine filter (S) with BEKOMAT
8 Sensor unit METPOINT
®
OCV
9 Evaluation unit with user interface (display) METPOINT
®
OCV
H1/H2 Shut-off valves of the measuring section
H3 Shut-off valve of the bypass
H4 Vent valve of the measuring section
The depicted installation shows the minimum requirement of the METPOINT
®
OCV in combination with a compressor
with oil-free compression. Other types of installation are possible (provided that they meet the defined operating
conditions).
For service measures, it is recommended to install a bypass at the METPOINT
®
OCV. This applies generally to all
components to be serviced in compressed-air systems.
Please observe that this bypass must also be free from oil and grease!
CAUTION!
Contaminated input air – inferior operating conditions!
When employing the METPOINT
®
OCV under inferior operating conditions, the device can be contaminated,
damaged or destroyed!