BEL DIGITAL AUDIO
BM-A1
BM-A1 serial protocol
2004 BEL (Digital Audio) Ltd
18
Version 0.2
Red zone data
The numerical value of the five bits of the red zone data corresponds to the length of the red
zone. The origin of the red zone if the top of the bar graph.
Amber zone data
The numerical value of the five bits of the red zone data corresponds to the length of the
amber zone. This zone is ‘attached’ to the bottom of the red zone.
Bar type
These 3 bits select the bar ballistics and type.
Code
Bar type
000
AES
001
DIN
010
VU
011
BBC
100
Extended VU
101
Nordic
Bar peak indicator
These two bits select the peak indicator timing.
Code
Time
00
No peak indicator
01
3 Second hold time
10
7 Second hold time
11
Indefinite hold time
AES offset
This bit selects the bar graph offset when AES is input to an analog bar graph.
Code
Function
0
-18dB
1
-20dB