MECHANICAL DIMENSIONS 

Fig. 2   Mechanical Dimensions 

 
COOLING 
 

The  power  supply  should  have  thermal  connection  with  low  thermal  resistance  between  aluminium  plate  of  the 
power supply unit and liquid cooling cold plate. The temperature difference of contact area of cold plate and power 
supply should be <5

°

C at worst case (total power dissipation of each PSU max. 300W). Recommended is to use 

heat transfer paste with thermal conductivity 2.5 W/m.K between unit and cold plate (surface roughness Ra = 3.2 
of the aluminium plate is acceptable).  
Recommended tightening torque of M4 screws for assembling unit to aluminium cold plate is 3.5 - 4 Nm.

1)

  

 

Note 1)

: Recommendation is for thread cut in aluminium plate, thread length 10mm. Tightening torque depends on the material 

hardness of the used aluminium cold plate and used screws.    

 

Summary of Contents for TCP4000-H090

Page 1: ...ormity registration Therefore the sellers and users are required to take caution in this regard 2 The AC Leakage Current exceeds 3 5mA at maximal input voltage and frequency 3 x 528Vac 60Hz Typical values are 1 8mA at input 3 x 200 208Vac L L 50 60Hz 3 0mA at 3 x 400Vac L L 50Hz and 4 1mA at 3 x 528Vac L L 60Hz 3 Switch off the input AC power before doing any intervention or manipulation with the ...

Page 2: ...assis Min 2 5 mm2 AC Line 1 L1 Input Power AC Fused Min 2 5 mm2 528 Vrms line to line 16 Arms per line AC Line 2 L2 Input Power AC Fused Min 2 5 mm2 AC Line 3 L3 Input Power AC Fused Min 2 5 mm2 POWER OUTPUTS CONNECTOR BUS BARS Connector type Bus bar see Fig 1 Mating part Ring terminal for M4 screw with appropriate cross section for wire SIGNAL NAME PIN TYPE SIGNAL REFERENCE LOW LEVEL HIGH LEVEL V...

Page 3: ...RS485 Half Duplex Differential pair 2 RS485 2B 60 mA 60 Ω 50 pF2 7 to 12 VDC 8 mA ADDR INIT IN 3 The unit s address change required SRTN 0 4 VDC 2 5 VDC 3 6 VDC 0 2 mA IN OK 4 AC Power Fail Warning open collector external pull up needed to max 7 V SRTN 0 4 VDC Pull up 7 VDC 10 mA OUT OK 5 Output Voltage Fault open collector external pull up needed to max 7 V SRTN 0 4 VDC Pull up 7 VDC 10 mA INHIBI...

Page 4: ...in to SRTN SRTN 0 4 VDC 2 5 VDC 3 6 VDC 0 2 mA SRTN1 8 Internal Ground Signal Return RS485 1B 9 RS485 Half Duplex Differential pair 1 RS485 1B 60 mA 60 Ω 50 pF2 7 to 12 VDC 8 mA RS485 2B 10 RS485 Half Duplex Differential pair 2 RS485 2B 60 mA 60 Ω 50 pF2 7 to 12 VDC 8 mA Not Connected 11 OT FAIL 12 Over Temperature PSU Fail open collector external pull up needed to max 7 VDC SRTN 0 4 VDC Pull up 7...

Page 5: ...ature difference of contact area of cold plate and power supply should be 5 C at worst case total power dissipation of each PSU max 300W Recommended is to use heat transfer paste with thermal conductivity 2 5 W m K between unit and cold plate surface roughness Ra 3 2 of the aluminium plate is acceptable Recommended tightening torque of M4 screws for assembling unit to aluminium cold plate is 3 5 4...

Reviews: