DURABLASTER
®
WHEEL CLEANER
1MANUL054
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
29
Maintenance
Disassembly Procedure
5. To remove the pneumatic cylinder from the rotation mechanism, perform the following:
Remove the (4) fasteners from the bottom of the base.
Remove the (3) fastener sets that secure the base to the tube assembly.
Remove the (3) sets of shoulder bolts and bushings from the tube assembly.
6. Remove the base and pneumatic cylinder from the tube assembly. See the image below:
(3) fastener sets to secure
base and tube assembly
(4) fasteners from
bottom of the base
Base
Tube Assembly
(3) fastener sets with
(1) shoulder bolt and
(2) bushings each
Base
Tube Assembly
Pneumatic Cylinder