DURABLASTER
®
WHEEL CLEANER
1MANUL054
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
33
Maintenance
Trouble Shooting the DuraBlaster®
B. The DuraBlaster(s)® are not rotating properly or at all (Rotating Models ONLY)
Is only one
DuraBlaster®
rotating
properly?
Chances are extremely small that
both DuraBlasters® will fail
simultaneously, so
Troubleshoot the activation system
NO
YES
Open flow control found on back cover (note number of turns)
Step on Bell Hose
or Break Photo-eye
Do both
DuraBlasters®
rotate properly?
Verify that
pump is
programmed
to come on
for each car
and/or
appropriate
wash
packages
YES
NO
Press the manual override
button on top of the blue ‘Mac’
air valve on the air panel
Do both
DuraBlasters®
rotate properly?
NO
YES
Verify the
activation
device
pneumatic
and/or
electrical
components
(i.e.-photo-
eyes, bell hose
switch, hoses)
Do both
DuraBlasters®
rotate properly?
YES
NO-TOO FAST
1.
Clean out flow
control and air
lines.
2.
Reset the flow
control per the
Start up section
of this manual.
Do both
DuraBlasters®
rotate properly?
YES
NO
1.
Remove back cover
2.
Disconnect all air lines.
3.
Open small silver flow control
on the cylinder
(Use a small screwdriver and
turn CCW)
4.
Manually try to rotate cover
and manifold in both
directions.
5.
Raise and lower (3) shoulder
bolts in side of cylinder.
Do both
DuraBlasters®
rotate properly?
YES
NO
1.
Blow out both
flow controls
and air lines.
2.
Reset the flow
controls per the
Start up section
of this manual.
1.
Remove (3)
shoulder bolts
and bushings.
2.
Manually try to
rotate cover and
manifold in both
directions.
A
GO TO “A”
NEXT PAGE