insta-
KLEEN™ MANUAL
6
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL334
Introduction
IMPORTANT Safety Information
– MUST READ
Safety Warnings
CAUTION
–
SERVICE PERSON SHOULD USE APPROPRIATE FOOTWEAR AND
USE SAFETY CONSCIOUSNESS WHEN WORKING IN THE WASH BAY AREA.
WARNING
–
ELECTRICAL PANEL SHOULD BE MOUNTED SO THAT THE
DISCONNECT HANDLE IS BETWEEN 0.6
–
1.99 m (24
”–
78
”
) IN HEIGHT ABOVE
THE FLOOR WITH THE IDEAL HANDLE HEIGHT BEING 1.7 m (67
”
). LOCAL
COMPLIANCE FOR HANDLE HEIGHT MUST BE CONFIRMED.
WARNING
–
MINIMUM SERVICE CLEARANCE OF 900 mm (35.5
”
) IS
REQUIRED IN FRONT OF ICC CONTROLLER ENCLOSURE DOOR. LOCAL
COMPLIANCE OR SITE CONDITIONS MAY INCREASE THIS DISTANCE.
WARNING
–
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE
SERVICING ANY EQUIPMENT!
WARNING
–
HIGH
LEAKAGE
CURRENT.
EARTH
CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY.
3.3 mm
2
(Cu) MINIMUM FOR CE PANELS.
CAUTION
–
THE IP RATING OF THAT CABINET MUST BE MAINTAINED. FOR
EXAMPLE, USE ONLY STRAIN RELIEFS WITH AN IP RATING OF 66 OR BETTER.
WARNING
–
DO NOT OPERATE THIS EQUIPMENT FROM ANY POWER
SOURCE THAT DOES NOT MATCH THE VOLTAGE RATING LISTED ON THE
EQUIPMENT. REFER TO THE MANUFACTURER
’
S IDENTIFICATION LABEL FOR
OPERATIONAL REQUIREMENTS.
CAUTION
–
IT IS RECOMMENDED THAT A LICENSED ELECTRICIAN IS
CONTRACTED TO PERFORM ALL ELECTRICAL INSTALLATIONS.
CAUTION
–
ALL CONNECTIONS MADE TO THE ICC ENCLOSURE MUST BE
MADE THROUGH THE BOTTOM OF THE ENCLOSURE. HOLES ARE NOT PRE-
PUNCHED.
CAUTION
–
CLEANING IF IT SHOULD BECOME NECESSARY TO CLEAN THIS
EQUIPMENT, DISCONNECT THE UNIT FROM ITS POWER DURING CLEANING.
DO NOT USE LIQUID CLEANERS, AEROSOLS, ABRASIVE PADS, SCOURING
POWDERS OR SOLVENTS, SUCH AS BENZINE OR ALCOHOL. USE A SOFT
CLOTH LIGHTLY MOISTENED WITH A MILD DETERGENT SOLUTION.
CAUTION
–
A COMPRESSED AIR SYSTEM SHOULD BE SET CORRECTLY TO
SUPPORT 90 PSI / 620 kPa NECESSARY TO OPERATE EQUIPMENT BUT
SHOULD NEVER BE SET TO DELIVER MORE THAT 120 PSI / 827 kPa AIR
PRESSURE TO BELANGER® SPECIFIED EQUIPMENT. FIELD SUPPLIED
PNEUMATIC TUBING MUST HAVE A MINIMUM OF 2 TIMES THE BURST
STRENGTH OF SYSTEM PRESSURE.