Maintenance 

Metering Pumps 

1PUMP700 (Concentrate Pump), 1PUMP725 (Non-Concentrate Pump 

 

Summary of Contents for insta-KLEEN

Page 1: ...insta KLEEN System 1MANUAL334 Rev08 insta KLEEN System ...

Page 2: ...1MANUL334 REV 07 ...

Page 3: ...dditional copies of this manual or electronically transmit it in any form whatsoever in whole or in part without the prior written permission of Belanger Inc The registered trademarks used in this document are the property of their respective owners The use of such trademarks is for reference purposes only and does not imply sponsorship or approval of Belanger Inc by these companies or any compani...

Page 4: ......

Page 5: ...Wheel and Chameleon Arch descriptions 31 34 Added and updated Photo Eye section to manual 69 Changed 1CNTRL135 to 1CNTRL136 Changed 1ELECT DS150 to 1ELECT DS151 Changed 1ELECT MS045 to 1ELECT SW151 Removed 1ELECT DS156 3 1ELECT DS155 3 Added Note Following components attach here Shaft 1SHAFT151 Handle 1HANDLE151 Changed callout 1ELECT MO121 2 to Motor Starter 1ELECT MO121 2 or Soft Starter 1ELECT ...

Page 6: ......

Page 7: ...Getting Started 17 Guide Rails 18 Optional Above Ground Correlator 23 Optional In Ground Correlator 26 Optional Hydraulic Unit for In Ground Conveyor North American Option 27 Photo Eye Tunnel Placement 31 Positioning the insta KLEEN Control Center ICC 35 Placement 36 Electrical Enclosure Overview 37 Solution Delivery Overview 38 Utilities 39 System Startup 42 Initial Start up and Adjustment 42 Ope...

Page 8: ...LEEN MANUAL 2 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Table of Contents Appendix A CE Information 77 Appendix B De Commissioning Dismantling and Disposal 79 ...

Page 9: ...ash process and the following list includes some but not all of the particularly corrosive chemicals that if used in conjunction with Equipment or Parts will void the warranty Hydrofluoric Acid Ammonium Bi fluoride Bromic Acid Muriatic Acid Sulfonic Acid Phosphoric Acid Hydrogen Cyanide Hydrochloric Acid Sodium Hydroxide and Chlorinated Solvents 5 Seller makes no warranty express or implied with r...

Page 10: ...to the following categories Symbol Example Definition Yellow warning triangle black graphical symbol indicates what the hazard is Red circle with slash black graphical symbol indicates a prohibited action to avoid the hazard Blue mandatory action circles white graphical symbol indicates an action to take to avoid the hazard Terms used throughout the manual are defined as follows DANGER Indicates a...

Page 11: ...nery and equipment Doing so will prevent unexpected energization startup or release of hazardous energy while maintenance and servicing activities are being performed CAUTION EQUIPMENT OPERATES AT A VOLTAGE POTENTIAL WHERE ARC FLASH MAY OCCUR DISCONNECT THE UPSTREAM SOURCE AND USE MEANS TO LOCKOUT TAGOUT PRIOR TO OPENING FOR SERVICE WARNING BE SURE TO OBSERVE OPERATING ENVELOPE EQUIPMENT MAY START...

Page 12: ... MAINTAINED FOR EXAMPLE USE ONLY STRAIN RELIEFS WITH AN IP RATING OF 66 OR BETTER WARNING DO NOT OPERATE THIS EQUIPMENT FROM ANY POWER SOURCE THAT DOES NOT MATCH THE VOLTAGE RATING LISTED ON THE EQUIPMENT REFER TO THE MANUFACTURER S IDENTIFICATION LABEL FOR OPERATIONAL REQUIREMENTS CAUTION IT IS RECOMMENDED THAT A LICENSED ELECTRICIAN IS CONTRACTED TO PERFORM ALL ELECTRICAL INSTALLATIONS CAUTION A...

Page 13: ...ION TO LIFT AND OR HANDLE THE WEIGHT OF THE COMPONENT WHEN COMPONENTS ARE HANDLED BY HAND USE PROPER LIFTING TECHNIQUES TO AVOID INJURY WARNING DO NOT ATTEMPT TO SERVICE AREAS OF THIS EQUIPMENT ABOVE 1 8 M 6 FT WITHOUT WEARING AN APPROVED SAFETY HARNESS DO NOT ATTEMPT TO ACCESS UPPER AREAS OF THIS EQUIPMENT EXCEPT BY USING AN APPROVED SAFETY LADDER IN GOOD OPERATING CONDITION DO NOT USE TABLES CHA...

Page 14: ...nger Terms and Conditions of Sales describes the potential limitation of warranty due to your chemical selection 4 This warranty shall be void for all equipment failures and premature component wear caused by the use of corrosive chemicals in the wash process The following list includes some but not all of the particularly corrosive chemicals that if used in conjunction with Belanger equipment wil...

Page 15: ...R The dryer blowers have screens mounted to the inlet and outlets to prevent debris from entering and exiting the blower as well as to prevent contact with body parts Reasonable and Foreseeable Misuse The following conditions must be considered by the Owner Operator It is his her responsibility to take precautions as described below Do not allow users who are under the influence of alcohol drugs o...

Page 16: ...pumps without turning main power off and following Lock Out Tag Out Procedures Severe injury could result Ask questions when they arise DO NOT service without turning main power off and following Lock Out Tag Out procedures Severe injury could result Check amperage draw on all motors refer to motor name plate DO NOT attempt to add components to machine without first contacting Belanger Authorized ...

Page 17: ...embly pre wired and plumbed on the ICC A soap fan spray option can be added to apply a thick coating of presoak 4 Wave Across A second set of cloth mitters that oscillate from side to side for additional cleaning on the horizontal surfaces and the sides 5 Low Side Washer A low side washer to give added cleaning to the lower 36 91 cm of the vehicle Available in Neo Tex foam or cloth this option all...

Page 18: ...al market and assists in proper vehicle alignment guiding the vehicle throughout the length of the car wash 18 IK Vehicle Width Guide Rail Guide rail system that will capture and contain the entire vehicle and assists in proper vehicle alignment guiding the vehicle throughout the length of the car wash 19 Chameleon Arch The Chameleon Arch is made of quality aluminum and stainless steel constructio...

Page 19: ...ith 1 2 12 7mm and 5 8 15 8mm bit Forklift 5000 lb 2200kg Safety glasses Work gloves Field Purchased Supplies Needed for Installation 3HP 2 25kW air compressor What to Know Before You Get Started The insta KLEEN is a flexible system It can be ordered in many configurations and with many options Please check your order against your shipper and the equipment received Verify that you have received al...

Page 20: ...insta KLEEN MANUAL 14 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Introduction Lag Bolt Usage Guidelines 12 7 mm 12 7 mm 57 15 mm 57 15 mm ...

Page 21: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 15 Introduction Lag Bolt Usage Guidelines ...

Page 22: ...5A Pneumatic 3 HP air compressor Customer Supplied 225kW air compressor Customer Supplied 90 PSI minimum 120 PSI maximum 620kPa Minimum 827kPA Maximum Water fresh 1 1 pipe 18 GPM 40 PSI fresh water 25mm pipe 4m3 h 275kPa Water Reclaim if applicable 1 1 pipe 18 GPM 40 PSI fresh water 25mm pipe 4m3 h 275kPa ICC space requirements Dimensions Unit height 36 1 2 927mm Unit width 42 1 2 1080mm Unit dept...

Page 23: ...ter sections 60 1 524m Quantity will vary according to options purchased Yellow Guide Plastic Quantity will vary according to options purchased 10ft 3 048m Accessory Box Content quantities will vary according to options purchased 3 8 16 x 1 1 4 button head bolts 3 8 16 lock nuts 1 2 x 3 3 4 quick lags Measure the door opening at the entrance and the exit of the building Mark the floor at the cente...

Page 24: ... put on the guide rail opening will be 13 330mm as shown above After installing the Y Section you can begin to install the center sections and exit section 2 By using the alignment pins on the entrance end of all center sections slide the pin into the exit end legs of the previously installed sections Repeat until all sections are in place 3 Once all pieces are in place confirm that they are all p...

Page 25: ...lag bolts on each and set them aside 5 Locate the two 30 762mm plastic sleeves and slide them all the way down to the exit end of the Guide Rails as shown below 6 Slide the 10 foot plastic sleeves on both Guide Rails until you get close to the entrance Once near the entrance re install the Y Section as shown below 7 Take a measurement from the last piece of plastic to the plastic already installed...

Page 26: ...roperly aligned holes in the plastic for the supplied 3 8 16 x 1 1 4 button head fasteners and 3 8 16 center lock nuts on the underside of the guide rail Install fasteners in sequence down the rail to prevent the plastic from moving on the angle and causing hole misalignment 3 Repeat this process until all plastic pieces are in place and secure Tighten the nut and bolts down as you work your way d...

Page 27: ...e image 1 Remove the button head screw and nut shown below Discard the nut Loosen the lag bolt shown in image 2 to allow you to slightly lift the Guide Rail off the floor Locate the supplied support stanchion 2 Slide the stanchion into place as in image 3 and replace the button head screw into the tapped hole in the stanchion image 4 Secure the stanchion to the floor with 1 2 12 7mm lags image 5 I...

Page 28: ...g nuts as shown below The entrance elbows are mounted on an angle and the exit elbows are mounted straight Entrance Driver Side Entrance Passenger Side Exit Driver Side Exit Passenger Side Exit End Elbows Entrance Driver Side Elbow Entrance Passenger Side Elbow 9 After the Transition Elbows are installed grind the Plastic Guide Rail plastic of the Guide Rails to match the shape of the transition p...

Page 29: ...e following instructs you on how to install the Belanger Above Ground Correlator You will need to use the information in this document along with your site specific drawings for a successful installation Note If there is a need to extend the Correlator and Y section to the outside of building locate the two 20 x 2 508mm x 50 8mm Y section tube extensions Cut to desired length Butt the tubing up ag...

Page 30: ...old the Y Section pieces in place as circled below 2 Remove the driver side entrance rail assembly 3 Slide the Correlator into position under the passenger side Y Section assembly You will have to slightly lift the Y Section to get the Correlator into place 4 Position the Correlator equal distance side to side between the Guide Rails and set the tunnel depth according to the dimensions stated belo...

Page 31: ...48 380 9681 25 Installation Optional Above Ground Correlator 5 Once positioned properly locate four supplied lag bolt and secure the Correlator to the floor as shown below 6 Replace the driver side Y Section assembly 7 Locate the passenger side Correlator Frame and position it as shown below 60 1524mm ...

Page 32: ...Section to ease the transition even more The design of the In Ground Correlator does not allow much flexibility in the placement of the Y Section since by this point the cement has been poured and the Correlator should already be in place Therefore the dimensions shown in this section are of the optimum placement even though your actual placement may vary slightly due to your specific installation...

Page 33: ...Over Under Conveyor a 5HP Hydraulic Unit is included The following is general information on the 3 available Belanger hydraulic units and specifics on the 5HP unit Placement Place your Hydraulic Unit in the desired location and bolt it to the floor Be sure it is in a safe and dry environment IMPORTANT DO NOT EXCEED 1000 PSI OPERATING PRESSURE ON ANY SYSTEMS HYDRAULIC UNIT FAILURE TO STAY WITHIN LI...

Page 34: ... conducive to the maximum life of all hydraulic components Using Water Glycol Fluid has the best environmental qualities such as easy cleaning of cloth or foam cleaning up spills should a leak occur and easier maintenance of the reclaim pits If you choose a Water Glycol Based Fluid please select from one of the 3 recommended products listed below Houghto Safe 620 Houghton International www houghto...

Page 35: ...oses and connect the lines together to by pass the motor 4 Connect all feed lines and disconnect all return lines at the Hydraulic Unit and place in a bucket for draining 5 Close all flow controls and verify proper voltage and wiring 6 Bump the Motor Starter to verify proper motor rotation 7 Start the Hydraulic Unit and open each flow control until the fluid that comes out of the return hoses is c...

Page 36: ...escription The 5HP Hydraulic Unit is rated 6 GPM 1000 PSI with a 20 gallon steel tank Fluid Fill Cap Fluid Level Sensor Main Electrical Feed Speed Adjustment Control 1PUMP405 Snubber Knob Oil temperature and level Site Gauge 1GAUGE250 Oil Filter 1FILTR510 Return Pressure Gauge 5HP Hydraulic Motor Hydraulic Tank Rear Fixed Displacement Pump Feed Pressure Gauge Fluid Feed Manifold Fluid Return Manif...

Page 37: ...oto Eyes into place until you have read this entire manual The following shows basic placement of both styles The remaining pages will show mostly Floor mounted since both styles are similarly positioned Floor Mounted Once mounted the Photo Eyes are to be pivoted to point directly at each other Emitter Receiver Floor Mounted View from Entrance Floor Mounted Overhead View Photo Eyes are typically m...

Page 38: ... Mounted Once mounted the Photo Eyes are to be pivoted to point directly at each other Wall Mounted View from Entrance Emitter Receiver 16 40 6 cm 33 83 8 cm Photo Eyes are typically mounted with an approximate offset of 36 91 4 cm They can be mounted with a minimum offset of 6 15 2 cm up to a maximum offset of 120 3 0 m Wall Mounted Overhead View 36 91 4 cm ...

Page 39: ... However depending on the application the Photo Eyes could be spaced a minimum distance of 6 15 2 cm apart up to a maximum distance of 120 3 0 m apart Note Actual placement or tunnel depth may vary according to preference and or tunnel space available 36 91 4 cm 18 45 7 cm 40 1 02 m 90 2 29 m Emitter Receiver Emitter Receiver Overhead View Chameleon Arch with Floor Mounted Photo Eyes View from Ent...

Page 40: ...between the bed and cab of a pickup truck Note Actual placement or tunnel depth may vary according to preference and or tunnel space available 7 feet 2 13 m 7 6 2 29 m Place the receiver timer on the driver side of the tunnel Place the emitter on the passenger side of the tunnel Offset angle MUST be great enough so the light beams do not make contact between the bed and cab of a pickup truck 6 min...

Page 41: ...in the tunnel in case there is no back room in the building as long as the environment is safe from freezing temperatures The ICC has Solenoid Valves that must be covered to protect from dripping water The ICC is designed to be wall mounted on either the driver side or the passenger side of the tunnel whichever side the main utility feeds enter the building Traditionally the ICC is positioned firs...

Page 42: ...BLE FOR RE TIGHTENING ALL LUGS SET SCREWS AND TERMINALS LOCATED IN THE ELECTRICAL PANELS COMPONENTS MAY VIBRATE LOOSE DURING SHIPPING WARNING ELECTRICAL PANEL SHOULD BE MOUNTED SO THAT THE DISCONNECT HANDLE IS BETWEEN 0 6 1 99 m 24 78 IN HEIGHT ABOVE THE FLOOR WITH THE IDEAL HANDLE HEIGHT BEING 1 7 m 67 LOCAL COMPLIANCE FOR HANDLE HEIGHT MUST BE CONFIRMED ICC Shown Below Has Optional Valves and Pu...

Page 43: ...ion Electrical Enclosure Overview Circuit Breakers Motor Overloads Standard Configuration 1 Mitter Gyro Wrap 2 Side Wheels Motor Overloads Optional Configuration 2 Lower Side Wheels 2nd Mitter Gyro Wrap Output Board Programmable Logic Controller PLC Counter Terminal Strip Disconnect Zone 2 Motor Starter Zone 1 Motor Starter ...

Page 44: ... 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Installation Solution Delivery Overview Zone 1 and 2 Soap Optional Presoak Optional Drying Agent Rinse Arch Zone 2 Water Chemical Optional Presoak Zone 1 Water Chemical ...

Page 45: ... rear of the water manifold This can be Spot Free RO water if no Presoak option is installed 2 Install one reclaim water supply 1 25mm using a hose drop from copper to barbed hose fitting located on the front of the water manifold This can be Fresh water if no Reclaim is supplied Note It is recommended that a licensed electrician and a professional plumber are contracted to perform all of the elec...

Page 46: ...ith three valve assemblies Optional valve available for Presoak Injection Tee included on valve if Drying Agent option is purchased Optional Drying Agent Optional Presoak Zone 1 and 2 Soap System comes standard with one chemical pump Optional pumps available for Drying Agent and Presoak Injection Tee NOTE If one Rinse Arch for RO and the Presoak option was purchased remove the Rinse Arch Valve fro...

Page 47: ...104 and 105 Treadle Install the Floor Treadle according to site specific drawings 1 Wire switch normally open forced closed by a vehicle tire Verify input actuation at input X1 on PLC Input should be OFF with no car on treadle and turn ON when actuated Photo eye Install the photo eye according to site specific drawings 1 Place photo eye in a location that provides a 12 offset from emitter to recei...

Page 48: ...plicable 16 Check Photo Eye operation by confirming that the input light X2 on PLC is ON when Photo Eye not blocked It should be OFF when Photo Eye blocked Check both states 17 Check Treadle operation if treadle installed by confirming that the input light X1 is OFF when not on the Treadle It should be ON when vehicle is on Treadle Check both states 18 If Conveyer installed check Roller count oper...

Page 49: ...ding style It s provided with solid state individual output modules Each output module has its own fuse and 3 position switch for ON OFF AUTO This system can control two zones of equipment conveyor Pre soak arch Rinse wax arch extra function dryers and Titans Electrical Enclosure The electrical enclosure houses the wash controls and motor starters for electric drive equipment All items inside this...

Page 50: ... 1 water off delay D148 Zone 2 water on delay D149 Dryer off delay D150 Extra function off delay D151 NOT USED D152 NOT USED D153 NOT USED D154 Program Version D155 Displays number of washed vehicles M Setting Screen This screen used to change display the setting of M500 to M509 To navigate among M500 to M509 press the OK key to get underline cursor flashing Once cursor is flashing use and keys to...

Page 51: ...is input must be on when not in use The input pulses off then back on again when Roller lifts trap door INPUT X4 Roller Recall front tire pull only This input must be off when not in use The input turns on when Roller call button pressed This input can only be used for calling another Roller if front tire didn t catch first Roller This is not a hot Roller input INPUT X5 Extra Function Photo The in...

Page 52: ...oto eyes or it is through photo eyes if it s the last car in wash Will turn off for same conditions if two cars in wash but second car has not yet turned on pre soak Output won t turn off if 3 cars is in wash OUTPUT O6 Zone 2 Equipment Will come on 3 second after Zone 1 equipment comes on Will turn off at same time as Zone 1 equipment OUTPUT O7 Zone 2 Water Will come on a user selectable number of...

Page 53: ...t has not yet turned on its pre soak Zone 1 water will never turn off if three or more vehicles are in wash A vehicle is considered out of wash when its through rinse arch photo eyes Range 1 60 D148 ZONE 2 WATER ON DELAY This is the delay in second before the Zone 2 water function will be instructed to run after vehicle enters wash Range 1 66 D149 DRYER OFF DELAY This is the amount of time after a...

Page 54: ...1 2 gives 2 Rollers when wash initiated Rear tire push no treadle M500 prevents the system from looking for treadle input and makes the number of Rollers on initiation equal to back Roller count Auto Roller M501 makes the wash initiate as soon as enable input is pulsed and calls for Rollers SYSTEM 2 This system has POS wash card button etc that is positioned at window when car has front tire only ...

Page 55: ...e You may need to increase pre soak on delay for better operation This style is possible but system 1 is preferred instead SYSTEM 5 This system does not have POS wash is enabled at all times This system has treadle that is used for both tires This system is front tire pull and vehicle should be put in neutral after front tire drives over treadle Relevant Setting M500 OFF M501 OFF D140 1 gives 1 Ro...

Page 56: ...ut Treadle M501 ON this makes the wash initiate from POS D140 0 D141 0 Rear tire push no treadle M500 prevents the system from looking for treadle Auto Roller M501 makes the wash initiate as soon as enable input is pulsed SYSTEM 8 This system has POS wash card button etc that is positioned at vehicle window before front tire gets to treadle Relevant Setting M500 OFF M501 OFF D140 0 D141 0 SYSTEM 9...

Page 57: ...erstood this cannot be overstated and has direct implications on vehicle damage and expensive equipment repairs One should look for equipment malfunction entangled debris clogged nozzles low chemicals etc These items are broken down and elaborated on in the following sections To keep the machinery clean nightly wash downs are recommended Weekly cleaning of the aluminum frames should also be done O...

Page 58: ...insta KLEEN MANUAL 52 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 59: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 53 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 60: ...insta KLEEN MANUAL 54 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 61: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 55 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 62: ...insta KLEEN MANUAL 56 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 63: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 57 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 64: ...insta KLEEN MANUAL 58 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 65: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 59 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 66: ...insta KLEEN MANUAL 60 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 67: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 61 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 68: ...insta KLEEN MANUAL 62 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 69: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 63 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 70: ...insta KLEEN MANUAL 64 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 71: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 65 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 72: ...insta KLEEN MANUAL 66 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 73: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 67 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 74: ...insta KLEEN MANUAL 68 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 75: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 69 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 76: ...insta KLEEN MANUAL 70 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 77: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 71 Maintenance Metering Pumps 1PUMP700 Concentrate Pump 1PUMP725 Non Concentrate Pump ...

Page 78: ...167 5470 Ph 248 349 7010 Fax 248 380 9681 1MANUL334 Maintenance ICC Parts Identification ICC Panel Motor Starter Configurations Fluid Manifold Assembly Part 102828 Total number of Motor Overloads included is determined by system configuration Optional Not Included ...

Page 79: ...09 1ELECT DS151 1ELECT SW151 1SPACR140 4 1ELECT CR650 1ELECT FS942 1ELECT RL942 4 1ELECT MS005 1ELECT MS008 Motor Starter 1ELECT MO121 2 or Soft Starter 1ELECT MS680 2 1ELECT MS017 1ELECT MO140 1ELECT FS959 1ELECT RL850 1ELECT FS002 1CNTRL136 Motor Overload part numbers vary See Electrical Prints Non CE 1ELECT FS955 31 CE 1ELECT FS972 31 Following components attach here Shaft 1SHAFT151 Handle 1HAN...

Page 80: ...10 Fax 248 380 9681 1MANUL334 Maintenance ICC Parts Identification Solution Delivery Components 1FTTNG BH335 4 1TEE BR690 2 1VALVE WA180 3 1VALVE WA276 4 1VALVE WA252 4 1PLUG BR380 4 1PLUG BR690 3 1REDUC BR300 PUMP105264 3 1ALMNM AN108 3 1FTTNG BH500 2 3944 1ELECT DN500 4 1MCONC BR745 4 ...

Page 81: ...insta KLEEN MANUAL 1MANUL334 Belanger Inc PO BOX 5470 Northville MI 48167 5470 Ph 248 349 7010 Fax 248 380 9681 75 Maintenance ICC Parts Identification Valve Assemblies 102147 102146 ...

Page 82: ...roper distribution of soap X Check cloth for wear and replace when needed X Check fluid level in gear box X Change fluid in gear box X Check arms for smooth movement X Grease shaft bearings 4 X Grease pivot bearings 4 X Check wear of Hitch Hiker disc X Check wear of isolation mount springs and bushings X UNIARCH Item Description Weekly Monthly Yearly Check and clean spray nozzles X Check for prope...

Page 83: ... and risk reduction EN 61000 6 2 2005 Immunity Standards for Industrial Environments EN 55011 2009 A1 2010 Group 1 Class A Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement The technical documentation for the machinery is available from Raffaele Morelli Technical Services Rep Europe PDQ Manufacturing Inc C ...

Page 84: ...lculated according to EN ISO 11204 Appendix A 3 dB A Equipment used for the measurements Center Model 325 S N 110909369 Calibration Method ANSI ASA S1 4 Type 2 IEC 651 Type 2 Date Place of the most recent calibration 22 MAY 2019 Good for 1 year Instrument Calibration and Technical Services 5312 Peters Road Suite E Roanoke VA 24019 USA The figures quoted are emission levels and are not necessarily ...

Page 85: ...LY DURING WASH USAGE AND INSTALLTATION ALSO APPLY DURING DISASSEMBLY AND DE COMMISSIONING HYDRAULICS LUBRICANTS MUST BE RECYCLED AS REQUIRED BY LOCAL ENVIROMENTAL LAW DO NOT DISPOSE OF BY POURING DOWN THE DRAIN ELECTRONICS MUST BE RECYCLED AS REQUIRED BY LOCAL ENVIRONMENTAL LAW DO NOT DISPOSE OF BY ADDING TO THE MUNICIPAL WAST STREAM METAL OTHER PARTS OF THE SYSTEM MUST BE RECYCLED AS REQUIRED BY ...

Page 86: ......

Page 87: ......

Page 88: ......

Reviews: