Belarus 1025/1025.2/1025.3
Section G. Scheduled maintenance
G 50
Operation 63. Diesel fuel pump.
Advance angle of fuel injection by the
pump should be in the range given in the
table. Only skilled personnel can check
and adjust angle of lead.
IMPORTANT!
Adjustment of fuel
equipment by tractor operator (owner) is
considered as grounds for cancellation of
manufacturer’s warranty obligations.
Dismount the pump and send to
check for compliance with
adjustment parameters.
Adjusting injection advance angle,
degrees to TDP
Д
-245
Д
-245S
Д
-245S2
22±1
13±1
3±0.5
Operation 64. Washing diesel cooling
system.
To wash the system use solution of 50-60
grams of soda ash per one liter of water.
Observe the following order of washing:
•
Fill radiator with two liters of kerosine
and fill the system with prepared
solution;
•
Start the diesel and let it operate for 8-
10 hours, then drain solution and rinse
the cooling system with pure water;
•
Check if radiator core is clean. If
necessary, wash the radiator and blow
off the core with compressed air
(blowing direction – from the diesel
side).
ATTENTION!
Radiator clogging,
insufficient tension of the fan belt,
contamination inside cooling system may
lead to diesel overheating and failure.
Summary of Contents for 1025 2008