Belarus 1025/1025.2/1025.3
Section E. Preparation for operation
E2
And in the flashing mode with 1 Hz
frequency the control lamp of the
parking brake alarm, and in
combination of instruments: the lamp of
emergency diesel oil pressure (the
buzzer is audible), air pressure indicator
(if it is lower of the allowable limit),
voltage indicator and fuel level indicator
(if fuel in tanks is on the reserve level);
•
Put starter switch key to position«II»
(«Start»).
•
Hold the key until diesel is started, but
for not more than 15 seconds. If diesel
doesn’t start, repeated start make not
earlier than 30…40 seconds. If after
three attempts diesel doesn’t start,
find out the cause and correct it.
•
After starting the diesel check
functioning of all indicating lamps and
instruments’ readings (cooling fluid
temperature, oil pressure in diesel and
GB, storage batteries’ charging, etc.)
Let diesel operate at 1000 rev/min until
pressure within operation range gets
stable.
•
Control lamp of the second SB
charging should go down after diesel
start. It means that the second 24 V
voltage SB is being charged by
means of the voltage converter. If
charging control lamp is still on after
diesel start, it means that the second
battery is not being charged, and the
cause has to be found and corrected.
.
IMPORTANT!
Your tractor is equipped
with turbo supercharged diesel. High
turbo supercharger revolutions require
proper lubrication during diesel start.
When starting diesel after prolonged
storage, use starter to rotate the
crankshaft for about 10 seconds
without fuel supply to provide
lubrication of turbo supercharger
bearings. Let diesel operate idle for
2…3 minutes before loading it.
Starting at low temperatures (+4°С and below)
1. Diesel is equipped with electric torch
heater
Important!
To avoid damage of power
gear, do not push or tow tractor to start
diesel.
Electric torch heater is efficient in the
ambient temperature range of from +4°
С
to - 20°
С
. It consists of tank (1) with
diesel fuel and heating element (2)
(spark plug, electromagnetic valve and
nozzle).
.
Never use ether substances to make start
easier when electric torch heater is
installed. The use of ether may lead to
explosion in the inlet manifold and serious
injury or mutilation. When ether means
are used to make start easier, disconnect
and insulate wiring of the electric torch
heater, installed on the suck-in diesel
manifold.
Summary of Contents for 1025 2008