1523.6-0000010 OM
36
ATTENTION: WHEN THE TRACTOR ON-BOARD SUPPLY VOLTAGE GOES UP ABOVE
19V THE INTEGRATED INDICATOR FULLY GOES OUT AND RECOVERS WHEN THE
ON-BOARD VOLTAGE FALLS BELOW 17V!
ATTENTION: PILOT SIGNALING LAMPS ARE ACTIVATED AND DEACTIVATED SYN-
CHRONOUSLY WITH CHANGING THE STATE OF SYSTEM SENSORS!
2.8.4 Description of testing the integrated indicator performance
Each time the power supply is on, testing of needle pointers and scale elements of the rear
PTO indicator is carried out in the integrated indicator. In this case the indicator needle
pointers move away from zero marks for one sec. (or the pointers flutter for not more than
one second on indicator zero marks) and also both annunciators of the rear PTO scale
range 6 and 10 get actuated (figure 2.8.1) as well as all segments of the rear PTO scale.
2.8.5 The order of the integrated indicator programming
2.8.5.1 Integrated indicator control panel
Figure 2.8.4 – Integrated indicator control panel
Control panel 16 (figure 2.1.1) makes it possible to perform manual programming of
the integrated indicator with buttons “Parameter” and “Value” (figure 2.8.4) and to change
the mode of displaying the parameters on LCD.
To get access to buttons “Parameter” and “Value” it is necessary to remove cover of
II control panel.
A diagnostic connector
ХР
1, located on the front surface of the control panel,
makes it possible to perform automatic programming (reprogramming) of the integrated
indicator (II) by means of a special device (if provided). In case such a device is not pro-
vided, the programming shall be performed by means of the above mentioned buttons. On
“BELARUS-1523.6” tractors, the
ХР
1 connector is not provided.
2.8.5.2 The algorithm of the integrated indicator programming
When choosing a fixed value of the parameter, the II programming is carried out in
the following way:
- when the “Parameter” button is pressed for the first time (see figure 2.8.4), multi-
function indicator 17 (figure 2.8.1) switches to the mode of viewing the programmed pa-
rameter and its numerical value. When the button is pressed repeatedly, the numerical
value of the set programmed parameter is changed;
- when the “Value” button is pressed repeatedly, the numerical value of the set pro-
grammed parameter is changed;
- when neither the “Parameter” nor “Value” button is pressed for 7.0 seconds, the
mode is exited automatically.
When exiting the mode, the last set parameter values chosen with the “Value” but-
ton are saved.
When choosing an unfixed parameter value of the integrated indicator program-
ming, it is necessary to do the following:
MODE
VALUE
PARAMETER