Installation MACH104-PoEP
Release 10 09/2019
7
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 38.
Connect to the product only components suitable for the requirements
of the specific application case.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Connect only PoE-supplier devices whose data connections are
located in the interior of the building and are specified as SELV
circuits.
Grounding the device
The device is grounded via the power supply connections.
Requirements for connecting electrical wires
Before connecting the electrical wires,
always
verify that the
requirements listed are complied with.
Requirements for connecting the supply voltage
Before connecting the supply voltage,
always
verify that the requirements
listed are complied with.
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Only switch on the device when the casing is closed.
Relevant for North America:
Exclusively use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire.
Prerequisites:
All
of the following requirements are complied with: