PX106545-EN, Rev.A
39
6.4
OPTION
To display options menu, press
and then select
“OPTION”
menu with
button. This displays options menu as follows.
6.4.1
Splice operation
Splice operation consists of five sub-checkboxes. As the user marks a checkbox, each
function is activated.
Set Value
Description
Auto
Splice automatically starts when closing the wind cover.
Pause 1
It temporarily stops after the first alignment is finished.
Press
to advance to the next step.
Pause 2
It temporarily stops after clad alignment is finished.
Press
to advance to the next step.
Auto Heat
Heater automatically operates after splice is finished.
Auto Heat 2
Heater operates only when the fiber is located heater inside.