18
Cable Installation
Initial Power On
System Bring-Up
For bring-up of a switch system , see Configuring Network Attributes.
Configuring Network Attributes
The procedures described in this chapter assume that you have already installed and powered
on the system according to the instructions in this document. The system comes with a pre-
configured DHCP. If you wish to disable it, refer to Disable Dynamic Host Configuration Protocol
(DHCP). In case a manual configuration is required, please refer to the instructions in Manual
Host Configuration.
3.13.1.1Manual Host Configuration
To perform initial configuration of the system:
Step 1. Connect a host PC to the Console RJ45 ( ) port of the system, using the supplied
harness cable (DB9 toRJ45). Make sure to connect to the Console RJ45 port and not to the
(Ethernet) MGT (
) port.
Step 2. Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera
Term) on your host PC with the settings described in the table below. Once you perform
that, you should get the CLI prompt of the system.
Serial Terminal Program Configuration
Step 3. Login as admin and use admin as password. On the first login, the configuration
wizard will start.
Step 4. To configure network attributes and other initial parameters to the system, follow
the configuration wizard as shown in the Configuration Wizard Session table on the next
page.
Parameter
Setting
Baud Rate
115200
Data bits
8
Stop bits
1
Parity
None
Flow Control
None