22
Cable Installation
Initial Power On
Remote Connection
Once the network attributes are set, you can access the CLI via SSH or the WebUI via HTTP/
HTTPs. To access the CLI, perform the following steps:
1. Set up an Ethernet connection between the system and a local network machine using a
standard RJ45 connector.
2. Start a remote secured shell (SSH) using the command: ssh -l <username> <IP_address>
3. Login as admin (default username is admin, password is admin).
4. Once you get the CLI prompt, you are ready to use the system.
FRU Replacements
Power Supply
Grass Valley systems that are equipped with two replaceable power supply units work in a
redundant configuration. Either unit may be extracted without bringing down the system.
# ssh -l <username> <ip_address>
Grass Valley Switch Management
Password:
Note:
The following information does not apply to the GVF-516-100G. The
GVF-516-100G includes two non-replaceable power supply units and four
non-replaceable fan units
IMPORTANT: Make sure that the power supply unit that you are NOT
replacing is showing green for the power supply unit LED.
IMPORTANT: Power supply units have directional air flows similar to
the fan module. The fan module airflow must coincide with the
airflow of all of the power supply units. If the power supply unit
airflow direction is different from the fan module airflow direction, the
system's internal temperature will be affected. For power supply unit
air flow direction, refer to Air Flow.