28
Interfaces
Data Interfaces
System Status LED Assignments
Fan Status LED
Fan Status LED in GVF-1032-100G - Front and Rear Sides
Fan Status LED in GVF-516-100G
Fan Status Front LED Assignments
Fan Status Rear LED Assignments (One LED per Fan)
IMPORTANT: It may take up to five minutes to turn on the system. If
the System Status LED shows red after five minutes, unplug the
system and call your Grass Valley representative for assistance.
LED Behavior
Description
Action Required
Solid Green
The system is up and running
normally
N/A
Flashing Green
The system is booting up
Wait up to five minutes for the end
of the booting process.
Solid Red
Major error has occurred. For
example, corrupted firmware,
system is overheated etc.
If the System Status LED shows red
five minutes after starting the
system, unplug the system and call
your Grass Valley representative for
assistance.
Both of these LEDs in the red ovals
show the fans' status.
The GVF-516-100G systems have a front fan LED only.
LED Behavior
Description
Action Required
Solid Green
All fans are up and running.
N/A
Solid Red
Error, one or more fans are not operating properly. The faulty FRUs should be replaced.
Off
System boot
N/A
LED Behavior
Description
Action Required
Solid Green
A specific fan unit is operating.
N/A
Solid Red
A specific fan unit is missing or not operating
properly.
The fan unit should be replaced.
Off
System boot
N/A