63
IQH3B/IQH3BQ
User Manual
Examples of Slot Use
Intentionally Empty Slot
If a slot is intentionally left empty, the
Installed Unit Name
field will show
No Unit Fitted
and
the
Installed Unit ID
field will show
No Unit
.
The
Editable Name
field will be empty and the
Bound Type ID
window will display
None
.
In the absence of other modules, the Gateway does not log
Module Status
for this slot
position.
Correct Module Fitted
If a module is fitted that matches the
Bound Type
, the
Editable Name
is used in the network
browser.
In the absence of other modules, the Gateway will log
Module Status
as
OK
, and display
Module Status = OK
on the
Logging
page. The Gateway also logs
MSG=UNIT PRESENT
for
the slot position.
Module Absent - Unit Bound
If a slot is intended to have a particular module fitted (as set by the
Bound Unit
function), but
no module is fitted, the
Installed Unit Name
field will display
No Unit Fitted
and the
Installed
Unit ID
field will display
No Unit
. However, the
Editable Name
field will show the intended
name and the
Bound Type ID
field will display the intended ID.
In the absence of other modules, the Gateway will log
Module Status
as
1 Module Missing
,
and show
Module Status = 1 Module Missing
on the
Logging
page. The Gateway also logs
MSG=UNIT LOST
for the slot position.
Module Fitted - No Bound Unit
If a module is fitted in a slot but no
Bound Type
is assigned to the slot, the generic type name
for the module type will be displayed, and the slot will appear in the network browser by its
slot number and generic type.
In the absence of other modules, the Gateway will log
Module Status
as
1 Extra Module
, and
show
Module Status = 1 Extra Module
on the
Logging
page. The Gateway also logs
MSG=UNIT PRESENT
for the slot position.
Incorrect Module Fitted
If a module is fitted that does not match the
Bound Type
, the
Editable Name
will not be used
and the generic type and slot number will appear in the network browser.
In the absence of other modules, the Gateway will log
Module Status
as
1 Wrong Module
,
and show
Module Status = 1 Wrong Module
on the
Logging
page. The Gateway also logs
MSG=UNIT PRESENT
for the slot position.
Non-RollCall Module Fitted
If a card that is passive to RollCall is fitted in a slot, enable the
Non RollCall Enable
check box.
The Gateway will simulate a RollCall-compatible card in the relevant slot, and raise awareness
to RollLog and RollMap. In the
IDNAME
field, enter a name for the unit so that it can be
recognized.
For the module, the Gateway will log
MSG=NON ROLLCALLMODULE
, and
IDNAME=<user defined>
.
Summary of Contents for grass valley IQH3B Series