134
KAYENNE K-FRAME — Installation & Service Manual
Section 5 — Basic Configuration
Alternative Source Names
Alternative names can be assigned to sources for the convenience of pro-
duction personnel. For example, you may give the cameras menu names
that include the operator (C1 Bob, C2 Phil, and C3 Bill), but remove the
operator names from the OLED names to show C1, C2, and C3 in larger
characters. These alternative names are entered in the Source Patch menu.
The User Setups, Suite Prefs, Source Patch menu (
) has three edit-
able columns for defining up to three alternative names:
A
Panel Name
is limited to four characters, to fit the space available on the
Control Panel’s Transition Module. This name is only displayed on the
Control Panel.
An
OLED Name
appears only on the Source Name Displays on the Control
Panel. Up to eight characters are displayed.
A
Menu Name
is limited to eight characters, and appears on all the GV
Switcher menu application screens except Engineering Setup menus,
which always display engineering IDs or names.
Multiple Suites and Source Names
Different sets of these alternative source names are defined for each
Kayenne K-Frame suite. Ensure the GV Switcher menu application you are
using is logged into the correct suite (
Eng Setup
,
Eng Login
). The same set of
engineering names will be used by both Kayenne K-Frame suites, however.
Name Display Hierarchy
If a source’s engineering name is left blank, the Eng ID number will be
used. If no alternative names are defined for that source, then that Eng ID
number will appear on all the Kayenne K-Frame system displays.
If an engineering name has been entered then the engineering name will be
displayed on all the Kayenne K-Frame system displays, including menus.
Engineering names will be truncated to the character limits of the display,
starting with the first character.
For alternative names entered in the User Setups, Suite Prefs, Source Patch
menu (
), the following rules apply:
For the three editable columns:
Panel Name
,
OLED Name
, and
Menu Name
, if any
of the three are left blank for that source, the first name to the left appears
in that display on the system (if all three are left blank, the name in the Eng.
Source Column is displayed). For example, if an alternative name is entered
in the OLED Name column for a source and the other two columns remain
blank, the Menu Name takes the OLED Name (OLED Name being first to
the left of the Menu Name) but the Panel Name takes the Eng. Source
column’s name (first name to its left). If names are entered in all three alter-
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...