KAYENNE K-FRAME — Installation & Service Manual
211
Ports & Devices
Figure 139. PBus Ports Menu
PBus Devices
– One of the twenty four available PBus devices can be selected
on the upper left side of the menu. Once selected, the remainder of the
menu is delegated to that PBus device.
RS422 Port Select / Status
– The button for the port currently assigned to the
selected item will be highlighted. Touching
None
clears the port assignment.
Baud Rate / Parity
– Serial port settings are selected with these buttons. The
Set Default
button returns the settings to the Kayenne K-Frame factory
defaults.
PBus Name
– Touching this button opens an alphanumeric keypad used to
give the PBus device a descriptive name. These names appear on the sepa-
rate Devices, PBus and PBus & GPI Enables menus, to help the operator
identify each function.
Set PBus Address
– Touching this button opens a keypad allowing entry of a
PBus address, which is required if multiple PBus devices use the same port.
Unassign PBus Device
– Clears the name of the selected PBus device and also
clears its port assignment.
Trigger Names
– Names can be entered for each of the 16 PBus triggers (0-15),
by touching each button.
Clear Names
– Removes the names from the currently selected PBus device.
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...