KAYENNE K-FRAME — Installation & Service Manual
— Maintenance
3.
After the files have been copied, the entire contents of the directory
should be compressed into a .zip archive. Grass Valley Customer
Support can provide instructions on how to send this information to the
GV engineering team for analysis.
Control Panel Module Diagnostics
On Control Panels, boot information/diagnostic is shown on the left most
character display of every panel board. This information (
immediately visible after a power cycle and present until the application
software writes the first data to the character displays
Example codes are shows in
Table 18. Control Panel Board Boot Display Codes
Digit
3
2
1
0
Digit Zero shows the link and FPGA boot status
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
+
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary.
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over application area (normal/default).
!
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary!.
Digit 1 shows the lower number of the FPGA firmware version.
Digit 2 shows the middle number of the FGPA firmware version.
Digit 3 shows the upper number of the FPGA firmware version. (X1 always shows “!” to see the difference to the released versions).
Table 19. Control Panel Module Boot Display Codes Examples
Digit
0
3
7
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
+
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary.
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
!
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area --> application area damaged, reprogramming necessary.
3. FPGA firmware version is 038 (DS1281.038).
!
3
5
*
1. Module interface link is working (normal/default).
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.035).
!
3
5
1. Module interface link is not working: link should come up after 1-3 seconds, if not there may be a hardware problem.
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.038).
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...