254
KAYENNE K-FRAME — Installation & Service Manual
— Maintenance
CAUTION
Do not power down or reset the Frame during the update process, HAD pro-
gramming takes several minutes to complete.
9.
Once the programming is completely finished, power cycle the Frame
to complete the HAD update process.
10.
To verify the update, enter checkHADs at the prompt:
->checkHADs
Result:
HADs up-to-date if value is:
value = 1 = 0x1
HADs out-of-date:
value = 0 = 0x0
(followed by a list of out-of-
date HADs)
Figure 182. Updated HAD Example Menu
Update the HAD FPGA Using a Telnet Session
1.
Open a Telnet Session to the Frame by clicking on the Windows Start
menu and entering
telnet
, space, <
Frame IP Address
> (example: telnet
10.10.10.100) in S
earch programs and files
.
2.
To check the HAD status, enter checkHADs at the prompt:
->checkHADs
Result:
HADs up-to-date:
value = 1 = 0x1
HADs out-of-date:
value = 0 = 0x0
3.
Enter the console menu by typing consoleMenu at the prompt:
->consoleMenu
.
Result:
Figure 183. Telnet Frame List
4.
Enter the number nine [9] for the Debug menu, at the prompt:
->9
Result:
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...