KAYENNE K-FRAME — Installation & Service Manual
263
SNMP Monitoring
Video Processor Frame
Control Panel
Menu Panel Processor
The Menu Panel Processor (the PC running the Menu application) can be
monitored separately, using the standard built-in Windows SNMP capabil-
ities and a third-party NMS. No unique Grass Valley MIB entries or traps
are available.
SNMP Installation
Grass Valley K-Frame switchers system devices have SNMP Agent soft-
ware already installed. No user installation is required.
Separate NMS software (third party package) will need to be installed onto
a PC that resides on the switcher network. Refer to the documentation pro-
vided with the NMS for installation instructions.
Table 22. Supported K-Frame Video Processor SNMP Monitoring
System Information
High level information regarding the Video Processor Frame including operating system,
name, location, serial number, software revision and high level frame state.
Module
Each plug in board slot in the Frame is a module (Controller, ME or eDPM). Information
is provided regarding the board plugged into the slot and the current state of the slot.
Power Supply (Up to 3)
Reports power failure if a power supply fails or is not present.
Thermal
High level temperature and fan status for the entire system. If a failure is reported here
then look at Fans or Temperature Sensor categories for details.
Fans
Detailed speed and status for each fan in the frame. Five fans are on the compact frame
and one fan in the standard frame. Typically inspected if Thermal category is reporting a
cooling problem.
Temperature Sensors
Detailed information from each monitored temperature sensor on the Frame. Typically
inspected if Thermal category is reporting a cooling problem.
Video Sync
Status of external video reference signal and what type of signal is present.
Network Configuration Data
IP address, Gateway and Netmask settings for external facing network interfaces.
Table 23. Supported Kayenne/Karrera K-Frame Control Panel SNMP Monitoring
Fan (3 or 2)
Kayenne: PCU has three fans.
Karrera: 2ME Control Panel has one fan, 3 ME has two fans.
Power Supply (2)
Will report power failure if a power supply is not present or not plugged in.
Temperature (2 or 3)
Kayenne: One ambient temperature, one on CPU.
Karrera: One ambient temperature, one on the Panel Processor FPGA, one on CPU.
Modules (Control Panel boards)
Status change traps are sent when a module is connected or disconnected.
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...