268
KAYENNE K-FRAME — Installation & Service Manual
— Maintenance
Video Processor Frame Traps
Table 24. Supported K-Frame SNMP Traps
Name
Type
Description
Severity
vsmPowerSupplyStatusChange
status
If the current status is different than the last
status then a trap is sent. A power supply OK
message is only sent if all power supplies are
OK after one of more power supplies have
failed or been removed. At boot time, the first
running status generates an informational
message. After that, a transition to the running
status generates a normal message.
comm error = alarm
fault = alarm
power supply removed = warning
power supply OK = normal
vsmFanStatusChange
status
If the fan board is not present or if all fans have
stopped working a trap is sent. This trap is
resent every 12 seconds until the condition is
corrected.
If any of the fans are not working properly a
trap is sent. This trap is resent every 20 sec-
onds until the condition is corrected.
When the system starts running normally or
returns from an abnormal condition to running
normally a trap is sent.
fan board not present = alarm
all fans not working = alarm
fan not working = warning
normal operation = informational (start up),
normal (returning from a warning or alarm condition)
vsmTempStatusChange
status
If temperature crosses the warm threshold in
any direction a trap is sent.
hot = alarm
normal = normal
vsmModuleStatusChange
powerOK
If the current power status is different than the
last power status a trap is sent.
power OK = normal
power Fault = alarm
vsmModuleStatusChange
status
If the current status is different than the last
status a trap is sent.
operational = normal
failed = alarm
not inserted = warning
vsmReferenceStatusChange
status
When the video reference transitions between
locked and not locked in either direction a trap
is sent.
not locked = warning
locked = normal
gvgElStateChange
status
When the switcher starts the boot process and
the trap status is “initializing” a trap is sent.
Another trap is sent when the switcher
becomes fully operational and the trap status
is “running”.
initializing = warning
running = normal
Summary of Contents for Grass Valley Kayenne K-Frame
Page 2: ......
Page 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Page 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Page 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Page 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Page 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...