K-Frame System Video Timing and Delay
Timing Analyzer
The Sync/Timing menu on Kayenne K-Frame systems (accessed via
Eng
Setup
,
Video Settings
) has a Timing Analyzer pane, which can help when
timing the system.
Figure 68. Video Settings Menu,
This analyzer reports the timing position of a selected source relative to the
Kayenne K-Frame internal sync generator. The source is selected with the
upper right
Analyzer Source
soft knob and data pad. The relative position of
that source is reported in lines and μs. Positive values indicate the source is
later in time than the internal sync generator, and negative values indicate
the source is earlier.
Kayenne K-Frame systems have an autotiming window. Sources that fall
within that window will be properly timed throughout the Kayenne K-
Frame system, even if the signal is cascaded through multiple MEs.
The
Switcher Horizontal
and
Switcher Vertical
soft knobs adjust the timing of the
Kayenne K-Framesystem relative to the incoming reference. These values
are generally best left at zero.