background image

7

[PRODUCT NAME]

[DOCUMENT TYPE]

12G-SDI Mainframe Rear Connectors

A

H

G

B

E

F

B

C

D

12G-SDI Mainframe Connectors

Connectors

Description

Connector Information

A

Output BNCs

12x HD/1080p (1.485Gbps / 2.97Gbps) Outputs.
Serial digital interface As REC601/ SMPTE/292M / 
SMPTE424M via BNC connectors.

Including 3 x 12G-SDI (11.88Gbps SMPTE 2082) single link 
BNC connectors (silver BNCs)

B

Input BNCs

42 x HD/SD/1080p (1.485Gbps / 2.97Gbps) Inputs.
Serial digital interface As REC601/ SMPTE/292M / 
SMPTE424M via BNC connectors.

Including 10 x 12G-SDI (11.88Gbps SMPTE 2082) single link 
BNC connectors (silver BNCs).

C

GPIO

44 GPI Tally/GPO Outputs Assignable GPI / GPO Isolated 
contact closures via 2 x 25 way D Type.
Assignable as GPI or GPO.

D

AES/LTC

4 x AES inputs and 3 x AES outputs with 1 x LTC input. (AES 
formal name is AES3-2003). LTC is Linear (or Longitudinal) 
Timecode.

E

Reference

1x Ref In and 1x Ref out

F

Network

3x 10/100/1000 base T

G

USB

2x USB3 - for external memory device or hard drives

H

Serial

2X RJ45, 4 x RS422 serial ports

Summary of Contents for grass valley MASTERPIECE 12G-SDI

Page 1: ...Installation Manual Issue 3 Rev 4 2020 01 29 MASTERPIECE MASTER CONTROL SWITCHER ...

Page 2: ...fully By using Masterpiece documentation you agree to the following terms and conditions Grass Valley hereby grants permission and license to owners of Masterpiece to use their product manuals for their own internal business use Manuals for GrassValley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any pur...

Page 3: ... may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing Indicates that the equipment has more than one power supply cord and that all power supply cords must be disconnected before servicing to avoid el...

Page 4: ...onnecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard use only the fuse type and rating specified in the service instructions for this product or on the equipment To avoid explosion do not operate this equipment in an explosive atmosphere Use proper lift points Do not use door latches to lift or move equipment Avoid mechanical hazar...

Page 5: ... Connect the grounding clip to an unpainted surface of the chassis frame to safely ground unwanted ESD voltages If no wrist strap is available ground yourself by touching the unpainted metal part of the chassis For safety periodically check the resistance value of the antistatic strap which should be between 1 and 10 megohms When temporarily storing a card make sure it is placed in an ESD bag Card...

Page 6: ...e borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire Signale la présence de composants sensibles à l électricité statique et qui sont susceptibles d être endommagés par une décharge électrostatique Utilisez des procédures des équipements et des surfaces antistatiques durant les interventions d entretien Le symbole ci contre signifie que l a...

Page 7: ...Utilisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous tension Avant de procéder à toute opération d entretien ou de dépannage enlevez tous vos bijoux notamment vos bagues votre montre et autres objets métalliques Pour éviter...

Page 8: ...eut se produire lorsque des composants électroniques ne sont pas manipulés de manière adéquate ce qui peut entraîner des défaillances intermittentes ou endommager irrémédiablement un circuit électrique Au moment de remplacer une carte dans un châssis prenez toujours les mesures de protection antistatique appropriées Assurez vous que le châssis est relié électriquement à la terre par le cordon d al...

Page 9: ...jamais ingérer le liquide La toxicité est extrêmement faible mais la prudence demeure de mise en tout temps Environmental Information European CE WEEE directive This symbol on the product s means that at the end of life disposal it should not be mixed with general waste Visit www grassvalley com for recycling information Grass Valley believes this environmental information to be correct but cannot...

Page 10: ...older using a blunt instrument for leverage such as a screwdriver if necessary In some cases the battery will need to be desoldered from the PCB 4 Dispose of the battery and equipment according to your local environmental laws and guidelines WARNING Be careful not to short circuit the battery by adhering to the appropriate safe handling practices Do not dispose of batteries in a fire as they may e...

Page 11: ...ow the beam should be treated with caution and common sense because it is intense and concentrated Laser radiation can cause irreversible and permanent damage of eyesight Please read the following guidelines carefully Make sure that a fiber is connected to the board s fiber outputs before power is applied If a fiber cable e g patchcord is already connected to an output make sure that the cable s o...

Page 12: ...netic Compatibility Limits for harmonic current emissions EN61000 3 3 2013 Electromagnetic Compatibility Limits of voltage changes voltage fluctuations and flicker EN55103 2 2009 Environment E2 Electromagnetic Compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity FCC CFR 47 Part 15 Class A Federal Commun...

Page 13: ...nections shall be made with high quality double screened coaxial cables such as Belden 8281 or BBC type PSF1 2M and Belden 1694A for 3Gbps D TYPE CONNECTORS D type connectors shall have metal shells making good RF contact with the cable screen Connectors having dimples which improve the contact between the plug and socket shells are recommended Note This equipment has been tested and found to comp...

Page 14: ...xiv Notices ...

Page 15: ...h Screen Monitor GUI 5 Mainframe Layout and Connections 6 Mainframe Overview 6 Masterpiece Mainframe Front Card Location 6 12G SDI Mainframe Rear Connectors 7 12G SDI Mainframe Connections 8 Inputs 8 Outputs 8 IP Mainframe Rear Connectors 9 IP Input and Output Connectors 11 USB 3 0 12 Network 12 NEX X4 and X5 12 Reference 12 25 Way GPIO 13 25 Way AES LTC 14 RJ45 RS422 Serial Ports 15 3 Location an...

Page 16: ... Surface External Power Supplies 22 5 Dimensions 23 Masterpiece Control Surface 23 Control Surface Desk Cutout Information 24 Masterpiece Mainframe Dimensions 25 6 Specifications 27 Masterpiece Control Surface 27 Masterpiece 12G SDI and IP Mainframes 28 12G SDI Mainframe Connections 29 IP Mainframe Connections 30 Contact Us 33 ...

Page 17: ...you have any questions regarding the installation of your product please refer to the contact details listed at the rear of this manual Masterpiece 12G SDI Mainframe Masterpiece Control Surface Masterpiece IP Mainframe Note Please note that all diagrams are for illustration purposes only and may differ slightly from the purchased product SAM operates a policy of continuous improvement and developm...

Page 18: ...2 About this Manual Overview ...

Page 19: ...sterpiece Control Surface allow external control MAV modules to be connected 2x Comms Ports Network Port to Mainframe 2x USB Connectors 2x External PSU Connectors Monitor Out 1 2 3 4 5 1 2 3 4 5 Masterpiece Control Surface Connectors 6 2x USB Connectors 6 Note The Control Surface Comms Ports are Comms ports not Ethernet ports DO NOT connect a Network Switch or Hub to any of the Comms ports Use CAT...

Page 20: ...onnectors Connector Description 1 2x PSU Connectors Kycon KPPX 4Pin or Compatible 12V DC 8 33A 2 2x USB 2 Connectors 3 Monitor MON Output to external touch screen 4 1x 10 100 1000 base T RJ45 network connectors to the switcher mainframe 5 2x Comms Connection Important Note NOT Ethernet connections must be direct to a Control Surface Do Not use network switches or hubs Use CAT5 or above cables Cros...

Page 21: ... user can connect a USB mouse to a USB port on the Control Surface and the HDMI to DVI for example lead to the monitor port Touch screen monitor once the external monitor is connected to the Masterpiece Control Surface a USB control lead shown above is connected allowing the touch screen functions to be used Non touch screen monitor once the external monitor is connected to the Masterpiece Control...

Page 22: ...ns Mainframe Layout and Connections Mainframe Layout and Connections Mainframe Overview The Masterpiece mainframe has 1 card which has all the Input Output video processing Masterpiece Mainframe Front Card Location Main Card ...

Page 23: ...85Gbps 2 97Gbps Inputs Serial digital interface As REC601 SMPTE 292M SMPTE424M via BNC connectors Including 10 x 12G SDI 11 88Gbps SMPTE 2082 single link BNC connectors silver BNCs C GPIO 44 GPI Tally GPO Outputs Assignable GPI GPO Isolated contact closures via 2 x 25 way D Type Assignable as GPI or GPO D AES LTC 4 x AES inputs and 3 x AES outputs with 1 x LTC input AES formal name is AES3 2003 LT...

Page 24: ...l that can output HD and 1080p 1 485Gbps 2 97Gbps Ten of those inputs with silver colored BNCs are inputs for 12G SDI SMPTE 2082 single link Outputs There are 12x SDI Outputs in total that can output HD and 1080p 1 485Gbps 2 97Gbps Three of those outputs with silver colored BNCs are outputs for 12G SDI SMPTE 2082 single link ...

Page 25: ...inputs 37 to 42 6x HD 1080p 1 485Gbps 2 97Gbps Inputs Serial digital interface As REC601 SMPTE 292M SMPTE424M via BNC connectors C GPIO 44x GPI Tally GPO Outputs Assignable GPI GPO Isolated contact closures via 2 x 25 way D Type Assignable as GPI or GPO D AES LTC 4 x AES inputs and 3 x AES outputs with 1 x LTC input AES formal name is AES3 2003 LTC is Linear or Longitudinal Timecode E Reference 1x...

Page 26: ...03 SMPTE 2110 SD HD 1080p outputs 1x50GbE A2 is the Secondary QSFP connection of the upper A card giving redundancy 1x50GbE B1 is the Primary QSFP connection of the lower B card Inputs 18 x SMPTE 2022 6 or VSF TR 03 SMPTE 2110 SD HD 1080p inputs across two 50GbE links Each 50GbE link transports 9 x SMPTE 2022 6 or VSF TR 03 SMPTE 2110 SD HD 1080p inputs Outputs 6 x SMPTE 2022 6 or VSF TR 03 SMPTE ...

Page 27: ... A and Lower B card giving redundancy Duplex signals supported over RTP streams via 2x QSFP 28 Transceivers QSPF28 SMPTE ST 2022 6 SMPTE ST 2022 7 VSFTR 03 VSFTR 04 SMPTE 2110 Up to 10 inputs 1 485 Gb s format sources Up to 10 inputs 2 970 Gb s format sources Up to 12 outputs 1 485 Gb s format sources Up to 12 outputs 2 970 Gb s format sources Input BNCs 6 x HD SD 1080p 270Mbps 1 485Gbps 2 97Gbps ...

Page 28: ...he list below describes the functions Connectors with XLR shells can be used to connect with these network connectors In each case LED Lit link Flashing traffic Left LED Right LED 1G bit 1000 base T GREEN GREEN 100Mbit 100baseT OFF GREEN 10Mbit 10baseT YELLOW GREEN No link OFF OFF NEX X4 and X5 NET X4 and NET X5 are used for direct connection from a laptop or PC for software updates to the IP Fins...

Page 29: ...28 5 GPO 8 5 GPO 30 6 GND 6 GND 7 GPO 11 7 GPO 33 8 GPO13 8 GPO 35 9 GPO 15 9 GPO 37 10 GPO17 10 GPO 39 11 GND 11 GND 12 GPO 20 12 GPO 42 13 GPO 22 13 GPO 44 14 GPO 1 14 GPO 23 15 GPO 3 15 GPO 25 16 GPO 5 16 GPO 27 17 GPO 7 17 GPO 29 18 GPO 9 18 GPO 31 19 GPO 10 19 GPO 32 20 GPO 12 20 GPO 34 21 GPO 14 21 GPO 36 22 GPO 16 22 GPO 38 23 GPO 18 23 GPO 40 24 GPO 19 24 GPO 41 25 GPO 21 25 GPO 43 Pin 1 P...

Page 30: ...nnector pins 45 66 AES LTC Pin outs AES LTC 45 66 Pin Signal 1 LTC 2 GND 3 Out 5 6 4 Out 3 4 5 GND 6 Out 1 2 7 In 7 8 8 GND 9 In 5 6 10 In 3 4 11 GND 12 In 1 2 13 NC 14 LTC 15 Out 5 6 16 GND 17 Out 3 4 18 Out 1 2 19 GND 20 In 7 8 21 In 5 6 22 GND 23 In 3 4 24 In 1 2 25 GND Pin 1 Pin 14 Pin 25 Pin 13 ...

Page 31: ...al equipment and a Slave setting lets Masterpiece be controlled by external equipment RS422 1 3 Pin Configuration RJ45 Pin Color typical Function master mode 9 pin D Type SP1 9 pin D Type SP3 1 Orange White Tx1B 3 2 Orange Tx1A 8 3 Green White Tx3B 3 4 Blue Tx3A 8 5 Blue White RX3A 2 6 Green RX3B 7 7 Brown White Rx1A 2 8 Brown Rx1B 7 Cable screen GND GND 9 9 RS422 2 4 Pin Configuration RJ45 Pin Co...

Page 32: ...inframe Rear Connectors The pin assignments for the 9 pin cable are as follows Pin Master Slave 1 Ground Ground 2 Rx A Tx A 3 Tx B Rx B 4 Tx Common Rx Common 5 Spare Spare 6 Rx Common Tx Common 7 Rx B Tx B 8 Tx A Rx A 9 Ground Ground ...

Page 33: ...n can be found on page 24 The Control Surface is secured into a desk using appropriate Pan Head M4 screws with a Max head diameter of 8 8mm 0 34 Inches At each end of the Control Surface there are two 4 5 mm 0 18 Inches fixing point holes for the screws as shown on the diagram below Note The Masterpiece Control Surface should preferably be mounted in a desk which is open underneath If the desk is ...

Page 34: ... that there is enough clearance for the connectors on the left side of the Control Surface The Control Surface is fastened to the rack system using 4x M6 1 4 inch screws screws are available from rack suppliers Once fastened to the rack insert all of the connectors making sure that the external PSUs do not hang from the side of the Control Surface the PSUs have to be supported Screw Holes Screw Ho...

Page 35: ...CTED Cooling Fan Failure IF THE COOLING FANS ONTHE SWITCHER MAINFRAME SHOULD STOP FOR ANY REASON THEN THE SYSTEM SHOULD BE SWITCHED OFF IMMEDIATELY OR PERMANENT DAMAGE MAY RESULT Depending on the length of time the mainframe has been run with no fan the unit may need to be returned for checking and repair Contact SAM or your SAM dealer to discuss the situation Warning Side view of the Masterpiece ...

Page 36: ...frame front door will have to be opened To do this unscrew the door locking screws on either side of the door then pull outwards and lower as shown in the diagram below 4 The mainframe is fastened to the rack system using 4x M6 1 4 inch screws screws are available from rack suppliers Note The Masterpiece Mainframe is heavy 14 5kg 31lb and will require two people to lift into position using correct...

Page 37: ... On at the AC mains supply Checking the Masterpiece Power Supplies Masterpiece mainframe power supplies are hot swapable Replacing power supplies should only be attempted by qualified personnel To see that the power supplies are working correctly when mains power is applied a green power LED is lit as shown below With the power supplies un plugged from the mains supply they can be individually rem...

Page 38: ...serviceable parts inside and are welded shut Do not attempt to open the power supply cases The power supply connector plug that connects to the Control Surface is a 4 pin Snap and Lock type care should be taken when connecting and un connecting Snap and Lock type connector Note Make sure that the mains power is turned Off before connecting the PSU to the Control Surface Note Do not allow the power...

Page 39: ...s Masterpiece Control Surface Masterpiece Control Surface Width Depth Height 482 3mm 19 Inches 265 9mm 10 47 Inches 169 8mm 6 69 Inches Weight Approx 4 7Kg 10 36lb Environmental 41 to 104 F 5 to 40 C non condensing ...

Page 40: ...24 Dimensions Control Surface Desk Cutout Information Control Surface Desk Cutout Information The desk cutout diagram for the Masterpiece Control Surface ...

Page 41: ...UMENT TYPE Masterpiece Mainframe Dimensions Masterpiece Mainframe Width Depth Height 482 6 mm 19 Inches 604 8mm 23 81 Inches 87mm 3 42 Inches Weight Approx 14 5Kg 31 96lb Environmental 41 to 104 F 5 to 40 C non condensing ...

Page 42: ...26 Dimensions Masterpiece Mainframe Dimensions ...

Page 43: ...orts 2x RJ45 connectors in total for Comms and 12V 0 83A power supply Do Not connect network switches or hubs to these ports Use CAT5 or above cables Crossover cables are Not suitable External Power Supplies Power Supply Description External PSU for the Control Surface 2x Fully independent external PSU modules with separate mains power feeds via 2x 10A IEC leads Output from each PSU 12V DC 100W vi...

Page 44: ... 94Hz ANSI SMPTE 260M 292M B 1080p 30Hz sF ANSI SMPTE 274M 12 as per RP211 1080p 29 97Hz sF ANSI SMPTE 274M 13 as per RP211 1080p 25Hz sF ANSI SMPTE 274M 14 as per RP211 1080p 24Hz sF ANSI SMPTE 274M 15 as per RP211 1080p 23 976Hz sF ANSI SMPTE 274M 16 as per RP211 1080p 30Hz ANSI SMPTE 274M 7 292M G 1080p 29 97Hz ANSI SMPTE 274M 8 292M H 1080p 25Hz ANSI SMPTE 274M 9 292M I 1080p 24Hz ANSI SMPTE 2...

Page 45: ...GPIO Reference Sync Input Output 1x Tri Level depending on output standard 1x On line Switchable between analogue 3Gbps HD Tri level Sync GPIO 2 x 25 Way D type programmable GPIO Tally with TTL level contact closure inputs for GPI AES LTC 1 x 25 Way D type AES LTC connector Signals 1 2 3 3 5 6 7 8 In 1 2 3 4 5 6 Out LTC Mainframe Inputs Inputs 42 x HD 1080p 1 485Gbps 2 97Gbps Inputs Serial digital...

Page 46: ...BNCs Input BNCs 4 x HD SD 1080p 270Mbps 1 485Gbps 2 97Gbps Serial digital interface as REC601 SMPTE 292M SMPTE424M via BNC connectors Including 1 x 12G SDI SMPTE 2082 single link BNC connector silver BNC IP Mainframe QSFP Inputs Outputs Formats Levels IP Input and Output Signals supported over RTP stream per rear module with 2 x 50GbE QSFP Cages QSFP Optical 2 x 50G Ethernet Conforms to IEEE 802 3...

Page 47: ...SU modules with separate mains power feeds via 2 x IEC sockets Dual Redundant requires two fully independent PSU modules with separate mains power feeds via 2 x IEC socket Inrush Current 6 0A Mainframe Power Supply Requirements Voltage 100V 240V 50 60Hz 5 2A Power 400 Watts Max 12G SDI and IP Mainframes ...

Page 48: ...32 Specifications Masterpiece 12G SDI and IP Mainframes ...

Page 49: ...in a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Reviews: