17
Location and Environment
Environmental Considerations
The ambient temperature for all the supplied equipment should not exceed the limits of 5 and
40
°
C (41 to 104
F) at a relative humidity of 10 to 90% (non-condensing).
Installing the equipment in a clean environment with moderate temperature and humidity will
promote a long and trouble-free equipment life.
Mounting the Masterpiece Control Surface into a Desk
With the desk cut to the correct size (desk cut-out information can be found on page 24).
The Control Surface is secured into a desk using appropriate “Pan Head” M4 screws with a Max.
head diameter of 8.8mm [0.34 Inches]. At each end of the Control Surface, there are two 4.5 mm
[0.18 Inches] fixing point holes for the screws (as shown on the diagram below).
Note:
The Masterpiece Control Surface should preferably be mounted in a
desk which is open underneath.
If the desk is not open underneath, enough room has to be left underneath
for ventilation and for routing the PSU and Comms cables to the underside
of the Control Surface.
It is essential to ensure the air temperature does not exceed 40
°
C.
Fixing point
Screw Holes
Fixing point
Screw Holes