6
Startup instructions ACA21-.../ACA22-...
Release 01 02/2014
Technical Data
General technical data
Order numbers ACA21-USB (EEC)
943 271-003
ACA22-USB (EEC)
942 124-001
ACA21-M12 (EEC)
943 913-003
ACA22-M12 (EEC)
942 125-001
USB standard
USB 1.1
ACA21-USB (EEC)
ACA21-M12 (EEC)
USB 2.0
ACA22-USB (EEC)
ACA22-M12 (EEC)
Storage
capacity
64 MB
ACA21-USB (EEC)
ACA21-M12 (EEC)
512 MB
ACA22-USB (EEC)
ACA22-M12 (EEC)
Connection type USB plug
ACA21-USB (EEC)
ACA22-USB (EEC)
5-pin M12 plug, A-encoded
ACA21-M12 (EEC)
ACA22-M12 (EEC)
Dimensions
ACA...USB...
3.66 in × 1.14 in × 0.59 in
(93 mm × 29 mm × 15 mm)
ACA...M12...
3.66 in × 1.14 in × 0.59 in
(93 mm × 29 mm × 15 mm)
Weight
ACA...USB...
1.76 oz (50 g)
ACA...M12...
2.47 oz (70 g)
Degree of
protection
ACA...USB...
IP20
ACA...M12...
IP67
Cable length
ACA...USB...
19.69 in (50 cm)
ACA...M12...
19.69 in (50 cm)
Power supply
Maximum rated voltage DC
5.5 V
Maximum current consumption 150 mA
Class 2
Ambient conditions
Climatic
conditions
during operation
Ambient air temperature
a
.
a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
−
40 °F ... +158 °F (
−
40 °C ... +70 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 795 hPa (+9842 ft; +2000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Climatic
conditions
during storage
Ambient air temperature
b
.
b. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
–40 ºF ... +185 ºF (
−
40 ºC ... +85 ºC)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)