Relevant for use in Ex Zone 2 according to ATEX 95
(European directive 94/9/EC)
In Ex zone 2, only devices with a corresponding label may be operated.
When operating the BAT-F types with the characteristic value G for
approvals 1 (ATEX zone 2), the following applies:
Never use the supply voltage with the characteristic value K in Ex
zone 2.
II 3 G
Ex nA IIC T4 Gc
−
40 °F ... +158 °F (
−
40 °C ... +70 °C ) for temperature range
with the characteristic value T and E
+32 °F ... +140 °F (0 °C ... +60 °C) for temperature range with
the characteristic value S
DEKRA 13ATEX0027 X
DO NOT OPEN THE DEVICE WHEN IT IS ELECTRICALLY CHARGED.
THE USB CONNECTOR MUST NOT BE USED WHEN THE DEVICE IS
OPERATED IN EXPLOSIVE HAZARDOUS LOCATIONS.
Special conditions for safe use
For supply voltage with the characteristic value C and W:
Take appropriate protective measures to prevent the voltage caused
by transients from exceeding 119 V on the working voltage
connection.
When the temperature under rated conditions exceeds 158 °F (70 °C)
on the cable or at conduit entry point, or 176 °F (80 °C) at the
branching point of the conductors, take measures so that the
temperature specification of the selected cable is in compliance with
the actual measured temperature values.
The modules shall be installed in a suitable enclosure in accordance
with EN 60079-15 providing a degree of protection of at least IP54
according to EN 60529, taking into account the environmental
conditions under which the equipment will be used.
Temperature code T4
Ambient temperature
−
40 °F ... +158 °F (
−
40 °C ... +70 °C ;
temperature range with the characteristic value ST and E)
Ambient tempe32 °F ... +140 °F (0 °C ... +60 °C;
temperature range with the characteristic value S)
List of technical standards
EN 60079-0:2012 + A11
EN 60079-15: 2010