Installation BAT-F
Release 09 08/2015
57
24 Mbps
16 dBm
-88 dBm
36 Mbps
15 dBm
-84 dBm
48 Mbps
13 dBm
-80 dBm
54 Mbps
12 dBm
-79 dBm
Data rate
Typical transmission
power
Typical receive sensitivity
1 Mbps
19 dBm
-94 dBm
11 Mbps
19 dBm
-94 dBm
Table 12: Receive sensitivity, transmission power and data rate according to
IEEE 802.11b
Data rate
Typical transmission
power
Typical receive sensitivity
06 Mbps
22 dBm
−
94 dBm
09 Mbps
22 dBm
−
94 dBm
12 Mbps
22 dBm
−
90 dBm
18 Mbps
22 dBm
−
89 dBm
24 Mbps
22 dBm
−
85 dBm
36 Mbps
21 dBm
−
82 dBm
48 Mbps
20 dBm
−
78 dBm
54 Mbps
19 dBm
−
77 dBm
Table 13: Receive sensitivity, transmission power and data rate according to
IEEE 802.11g
Data rate
Typical transmission power Typical receive sensitivity
MCS0
18 dBm
-87 dBm
MCS1
18 dBm
-90 dBm
MCS2
18 dBm
-86 dBm
MCS3
18 dBm
-82 dBm
MCS4
18 dBm
-79 dBm
MCS5
16 dBm
-75 dBm
MCS6
16 dBm
-73 dBm
Table 14: Receive sensitivity, transmission power and data rate according to
IEEE 802.11n and for the 2.412 GHz – 2.472 GHz bandwidth
Data rate
Typical transmission power
Typical receive sensitivity
Table 11: Receive sensitivity, transmission power and data rate according to
IEEE 802.11a