62
Installation BAT-F
Release 09 08/2015
EMC and immunity
MCS19
8 dBm
-84 dBm
MCS20
3 dBm
-81 dBm
MCS21
2 dBm
-77 dBm
MCS22
1 dBm
-75 dBm
MCS23
1 dBm
-73 dBm
EMC interference
immunity
EN 61000-4-2
Electrostatic discharge
Contact discharge, test level 4
± 8 kV
Air discharge, test level 4
± 15 kV
EN 61000-4-3
Electromagnetic field
80 MHz ... 1000 MHz
20 V/m
1400 MHz ... 2700 MHz
10 V/m
EN 61000-4-4
Fast transients (burst), test level 4
DC power line
± 4 kV
AC Power Line
± 4 kV
Data line
± 4 kV
EN 61000-4-5
Voltage surges
DC power line
± 2 kV line/ground; ± 1 kV line/line
AC Power Line
± 4 kV line/ground; ± 2 kV line/line
Data line, shielded
± 4 kV line/ground
Data line, unshielded
± 2 kV line/ground
Data line, unshielded
± 1 kV line/line
EN 61000-4-6
Conducted interference voltages, test level 3
150 kHz ... 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
EMC interference
emission
EN 55022
Class B
FCC 47 CFR Part 15
Class A
Stability
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
Shock
IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2,
EN 50155
Data rate
Typical transmission power
Typical receive sensitivity
Table 20: Receive sensitivity, transmission power and data rate according to
IEEE 802.11n and for the 5.180 GHz – 5.825 GHz bandwidth