2.5.3
Supply voltage with the characteristic value W
For
every
supply voltage to be connected, perform the following steps:
Connect the wires for the supply voltage according to the pin assignment
with a suitable socket.
2.5.4
Signal contact
Device variants featuring supply voltage with the characteristic value C, K
or W have a signal contact exclusively.
For the signal contact to be connected, make sure the following requirements
are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 52.
Connect the signal contact lines according to the pin assignment with a
suitable socket.
Plug the socket into the M12 plug on the device.
Type and specification of the
supply voltage
Pin assignment on the device
Nominal voltage DC
24 V
P-
Minus terminal of the supply
voltage
Voltage range DC incl. maximum
tolerances
18 V ... 32 V
N.C
.
—
N.C
.
—
P+ Plus terminal of the supply
voltage
Table 9:
Supply voltage with the characteristic value W: type and specification of
the supply voltage, pin assignment on the device
Pin
Function
1
Signal contact 2
2
Signal contact 2
3
Signal contact 1
4
Signal contact 1
Table 10: Pin assignment of the signal contact, 4-pin, A-coded M12 plug