background image

Installation BAT867-F

Release 01 12/2019

17

1

Description

1.1

General description

The devices allow you to set up WLANs (Wireless Local Area Networks) in a 
local network. In contrast to a conventional network connection through 
copper cables and fiber optic cables, some of the communication is 
performed by means of a radio link.
 
The devices allow you to install a new LAN or expand an existing LAN. 
Thanks to their high level of flexibility, the BAT867-F device is suitable for a 
wide range of applications. Anywhere that high bandwidths, stable operation 
and network security is required, WLAN with these devices provides the ideal 
solution.
 
The devices are dual-band industrial high-performance wireless LAN access 
points or clients complying with IEEE 802.11a/b/g/n/ac. They provide a high 
radio output with a bandwidth of up to 867 Mbit/s. The devices support MIMO 
(Multiple Input Multiple Output) and Multipath. The bandwidth is increased by 
using the multipath transmission by means of reflections. 2 antennas for 
sending and receiving help ensure stable network coverage with few shadow 
areas.
 
The device is designed for the special requirements of industrial automation. 
The device meets the relevant industry standards, provides very high 
operational reliability, even under extreme conditions, and also long-term 
reliability and flexibility.
The device works without a fan.
The device complies with the degrees of protection IP65/67.

There are convenient options for managing the device. Manage your devices 
via: 

Web browser

SSH

Telnet

HiDiscovery (software for putting the device into operation)

Management software (for example Industrial HiVision, LANconfig/
LANmonitor)

The device provides you with a large range of functions, which the manuals 
for the operating software inform you about. You can download these 
manuals as PDF files from the Internet on the Hirschmann product pages 
(

http://www.doc.hirschmann.com

).

Summary of Contents for Hirschmann BAT867-F

Page 1: ...Installation BAT867 F Release 01 12 2019 Technical support https hirschmann support belden com User Manual Installation Industrial Access Point Client Access Bridge BAT867 F...

Page 2: ...e performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to t...

Page 3: ...value P Power supply only through PoE 21 1 5 Ethernet port 21 1 5 1 10 100 1000 Mbit s PoE port 21 1 5 2 Pin assignments 22 1 6 Connections for antennas 23 1 7 Display elements 23 1 7 1 Device state...

Page 4: ...a 40 10 1 General technical data 40 10 2 Dimension drawings 41 10 3 Radio technology 42 10 4 Roaming 42 10 5 Receiving sensitivity transmit power and data rate 43 10 5 1 IEEE 802 11b 43 10 5 2 IEEE 80...

Page 5: ...malfunctioning device turn off the supply voltage and return the device to Hirschmann for inspection Certified usage Use the product only for the application cases described in the Hirschmann product...

Page 6: ...d objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Keep the ventilation slits free to ensure good ai...

Page 7: ...and operate this equipment with a minimum distance of 19 7 inches 50 cm between the antenna and your body Grounding the device For the functional earth FE there is a separate functional earth screw o...

Page 8: ...ents apply without restrictions The electrical wires are voltage free The cables used are permitted for the temperature range of the application case The connected voltage complies with the requiremen...

Page 9: ...hmann recommends a wire diameter of 0 5 mm to 0 75 mm AWG20 up to AWG18 The cross section of the ground conductor is the same size as or bigger than the cross section of the power supply cables The fo...

Page 10: ...an Union countries under the condition that it has been configured correctly In accordance with the above named EU directive s the EU conformity declaration will be available to the relevant authoriti...

Page 11: ...n the 5 GHz band channels Compliant operation of the device is achieved by an unchangeable determination of the country setting To obtain RED compliance perform the work steps described in chapter Obt...

Page 12: ...ecommunication services Registration at the Federal Network Agency is required Name and website of the competent authority Bundesnetzagentur www bundesnetzagentur de Ireland IE Frequency range 5725 MH...

Page 13: ...e with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause...

Page 14: ...mplies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada To reduce potential radio interference to other users the antenna type and its gain should b...

Page 15: ...ption safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with y...

Page 16: ...16 Installation BAT867 F Release 01 12 2019 Key The symbols used in this manual have the following meanings Listing Work step Subheading...

Page 17: ...upport MIMO Multiple Input Multiple Output and Multipath The bandwidth is increased by using the multipath transmission by means of reflections 2 antennas for sending and receiving help ensure stable...

Page 18: ...W WLAN module 12 Slot 2 9 Not assembled 13 Slot 3 9 Not assembled 14 Access point or client A Access Point C Client 15 Supply voltage 1 W Rated voltage 24 V DC with PoE support P Power supply solely...

Page 19: ...BAT867 F Release 01 12 2019 19 28 Configuration Z Accessory package 9 Not present 29 Device model H Hirschmann standard Item Characteristic Character istic value Description Table 3 Device name and p...

Page 20: ...r cable on the PoE PD port serves as the PoE power supply voltage The PoE power supply means that no separate power supply is required for your device 1 Antenna connection 2 2 Antenna connection 1 3 L...

Page 21: ...thernet port 1 5 1 10 100 1000 Mbit s PoE port This port is an 8 pin X coded M12 socket The 10 100 1000 Mbit s PoE port allows you to connect network components as a PoE power source according to stan...

Page 22: ...in 10 100 Mbit s 1000 Mbit s PoE applies to Twisted Pair port applies to PoE port 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Positive VPSE 4 TX BI_DA Positive VPSE 5 BI_DC Negative V...

Page 23: ...ce state These LEDs provide information about conditions which affect the operation of the whole device P Color Activity Meaning green lights up LED lights up after the configuration red flashing Devi...

Page 24: ...ressing the reset button replace the protection cap Degrees of protection IP65 67 are only achieved when the protection cap is closed You will find more information in the User Manual Configuration Gu...

Page 25: ...ng the device Connecting data cables Making basic settings Configuring the transmit power 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of d...

Page 26: ...itability of your device for IP65 67 proceed as follows Remove the provided transport protection caps and the transport protection screws from the device Seal unused sockets and plugs with your desire...

Page 27: ...from radio signals The terminating resistor is included in the scope of delivery for device variants with the Configuration characteristic value Z and available as accessory You will find information...

Page 28: ...trical interference levels Keep the length of the data cables as short as possible Use optical data cables for the data transmission between the buildings When using copper cables provide a sufficient...

Page 29: ...Installation BAT867 F Release 01 12 2019 29 Further information 10 100 1000 Mbit s PoE port on page 21...

Page 30: ...t time The device provides the following options for configuring IP addresses Entry via the HiDiscovery protocol in the applications HiDiscovery or Industrial HiVision Configuration via BOOTP You will...

Page 31: ...ime you log on to the device Log on to the device with the default password private The device prompts you to type in a new password Note When you log on with LANconfig the device prompts you to type...

Page 32: ...LANconfig software as an ISO image from the Hirschmann product pages www hirschmann com Perform the following work steps Command Line Interface CLI To access the possible country settings execute the...

Page 33: ...D compliance has been obtained To confirm your choice click the Send button Open the Extras RED compliance dialog Note To check the country setting and correct it open the Configuration Wireless LAN G...

Page 34: ...the row containing the desired device In the menu bar select Device RED compliance Note To check the country setting and correct it click the No button Then open the Configuration Wireless LAN General...

Page 35: ...ce proceed as follows In the menu tree open the Configuration Wireless LAN General dialog In the General tab specify in the General frame the country in which you install the device and click the Send...

Page 36: ...on BAT867 F Release 01 12 2019 Subtract the cable and installed overvoltage protector attenuation from the antenna gain Enter the calculated value in the Antenna gain field To save the value click the...

Page 37: ...m from the device It depends on the installation conditions of the device for example the distance from other devices or other objects and the output of neighboring devices The temperature displayed i...

Page 38: ...king on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and software downloa...

Page 39: ...Disable the supply voltage Disconnect the power supply cable Remove the antennas Disconnect the grounding WARNING ELECTRIC SHOCK Disconnect the grounding only after disconnecting all other cables Fail...

Page 40: ...d right device side 0 79 in 2 cm Ambient air temperaturea a Temperature of the ambient air at a distance of 2 in 5 cm from the device Devices with operating temperature characteristic value L standard...

Page 41: ...Installation BAT867 F Release 01 12 2019 41 10 2 Dimension drawings mm in 50 1 97 5 0 2 4 5 0 18 150 5 9 160 6 3 170 6 7 90 3 54 150 5 9...

Page 42: ...e and data rate Encryption IEEE 802 11i WPA2 with passphrase or IEEE 802 1x and hardware accelerated AES Closed Network WEP 64 WEP 128 WEP 152 User authentication 802 1x EAP LEPS WPA1 TKIP For more in...

Page 43: ...11b 10 5 2 IEEE 802 11g IEEE 802 11b Frequency range 2 412 GHz to 2 472 GHz Bandwidth 20 MHz Data rate Transmit power Receiving sensitivity 1 Mbit s 23 dBm 95 dBm 2 Mbit s 23 dBm 94 dBm 5 5 Mbit s 23...

Page 44: ...to 5 825 GHz bandwidth 20 MHz IEEE 802 11n Frequency range 2 412 GHz to 2 472 GHz Bandwidth 20 MHz Coding Transmit power Receiving sensitivity MCS 0 8 24 dBm 93 dBm MCS 1 9 24 dBm 91 dBm MCS 2 10 24...

Page 45: ...77 dBm MCS 6 14 19 dBm 74 dBm MCS 7 15 17 dBm 73 dBm Table 10 IEEE 802 11n frequency range 5 180 GHz to 5 825 GHz bandwidth 20 MHz IEEE 802 11n Frequency range 5 180 GHz to 5 825 GHz Bandwidth 40 MHz...

Page 46: ...7 dBm 73 dBm MCS 8 16 dBm 71 dBm Table 12 IEEE 802 11ac frequency range 5 180 GHz to 5 825 GHz bandwidth 20 MHz IEEE 802 11ac Frequency range 5 180 GHz to 5 825 GHz Bandwidth 40 MHz Coding Transmit po...

Page 47: ...dBm 84 dBm MCS 3 20 dBm 81 dBm MCS 4 20 dBm 77 dBm MCS 5 19 dBm 74 dBm MCS 6 18 dBm 73 dBm MCS 7 17 dBm 70 dBm MCS 8 16 dBm 67 dBm MCS 9 16 dBm 65 dBm Table 14 IEEE 802 11ac frequency range 5 180 GHz...

Page 48: ...d 2 kV line ground EN 61000 4 6 Conducted disturbances 150 kHz 80 MHz 10 V EMC interference emission EN 55032 Class A Immunity IEC 60068 2 6 test Fc Vibration 5 Hz 8 4 Hz with 0 14 in 3 5 mm amplitude...

Page 49: ...ction of the overall system is reduced to IP20 For reliable receive power and transmission power you require antennas that pertain to your application case Number Article 1 Device 1 Safety and general...

Page 50: ...ual is available for download on the Internet https www doc hirschmann com Designation Order number BAT ANT N 3AGN IP67 for N socket 10 pieces 942 110 001 50 terminating resistors for closing unused a...

Page 51: ...ontrollers Part 2 Equipment requirements and tests EN 62368 1 Equipment for audio video information and communication technology Part 1 safety requirements EN 300 328 Electromagnetic compatibility and...

Page 52: ...Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through netwo...

Page 53: ...Installation BAT867 F Release 01 12 2019 53...

Page 54: ......

Reviews: